Installation Instructions
7. Remove 13" (33 cm) foam tape from interior of
front panel. Refer to chart below for location.
Remove Foam Tape From Interior Of
Ice Machine Front Cover
Model Q320/370/420 or
Q, J or B 450/600/800/1000/1300/1600/1800
QuietQube Models Q600C/Q800C/Q1000C
GSI200 will be centered on the front panel.
Measure 6.5" (16.5 cm) left and right of center
Model Q200/280 or J - B 200/320/420
GSI200 will be offset ½" (1.27 cm) on the front panel.
Measure 6.0" (15 cm) left and 7.0 (17.8 cm) right of center.
Verify the ice machine control box cover screw aligns with a
slot in the sachet holder. This prevents bulging of the front
panel.
QuietQube Models IB600C/IB800C/IB1000C
GSI200 will be offset 3.5" (8.9 cm) to the left on the front
panel. Measure 10.0" (25.4 cm) left and 3.0 (7.6 cm) right of
center. Verify the GSI200 does not interfere with the water
curtain (at the ice thickness probe).
Q200/280 or J – B 200/320/420
Verify sachet holder does not rest on
control
box
cover
screw
before
permanently attaching to front panel.
8. Remove backing from double-sided tape on the
9. Locate the timer housing on the front panel where
10. Mark and drill four 3/32" pilot holes (two on top,
SV2091
11. Remove Ice Sentry sachet packet(s) from foil
12. Replace ice machine front cover
SV2095
7
Guardian GSI200
bottom of the timer housing.
the foam tape was removed in step 7, then press to
seal tape.
two at rear). Secure timer to front cover with
screws.
Top - Use two pan head screws
Rear – Use two flat head screws
Pan Head Screws
On Top
Flat Head Screws
On Rear
package and install into holder. Removing the foil
packet allows the moisture in the air to activate the
packet contents.
SV2098
SV2097
Need help?
Do you have a question about the GUARDIAN GSI200 and is the answer not in the manual?
Questions and answers