Specifications - Echo DIRECT VENT GAS HEATER Installation And Operating Instructions Manual

Table of Contents

Advertisement

ECHO

SPECIFICATIONS

Manifold Pressure
Min. Supply Pressure for
Purpose of Input
Adjustment
Max. Supply Pressure for
Purpose of Input
Adjustment
Orifice Size
Nominal Input Rating
Altitude
Primary Air Opening
Vent System
Log Set
Natural Gas (NG)
1.7 - 3.5 in. w.c.
5.00 in. w.c. (1.2 kPa)
7.0 in. w.c.
35# DMS
31,000 BTU/hr
0 - 2000ft. (0 - 610 m) US
0 - 4000ft. (0 - 1219 m) Canada
1/8in (Minimum)
Co - axial (4" x 7")
Ceramic (6 Piece)
5
DIRECT VENT GAS HEATER
Propane (LP)
3.8 - 10.0 in. w.c.
11.5 in. w.c.
13.0 in. w.c.
53# DMS
26,000 BTU/hr
0 - 2000ft. (0 - 610 m) US
0 - 4500ft. (0 - 1371 m) Canada
1/8in (Minimum)
Co - axial (4" x 7")
Ceramic (6 Piece)