Cleaning; Replacement Parts List - Echo DIRECT VENT GAS HEATER Installation And Operating Instructions Manual

Table of Contents

Advertisement

ECHO

Cleaning

To clean the stove, make sure the appliance is off
and cold. Then remove the logs and embers and use
a vacuum to clean burner and air openings in the
bottom and back of the appliance. Replace the logs
and embers.
It will be necessary to clean the glass periodically.
During startup, condensation, which is normal,
forms on the inside of the glass and causes dust, lint
etc. to cling to the glass surface. Initially paint,
while curing, may deposit a slight film on the glass.
It is recommended that, during the first few weeks
of use, the glass is cleaned two or three times with
non-abrasive common household cleaners and
warm water. Ammonia based cleaners should not be
used. Subsequently the glass should be cleaned two
or three times a season depending on the
circumstances. Do not clean the glass while it is hot.
Always close the window securely before lighting.
See Figure 24 for door removal, to clean inside of
glass. Do not clean glass with abrasive cleanser
or when hot.

REPLACEMENT PARTS LIST

Replacement parts are available at your dealer. The parts listed below are the only parts that the consumer may
replace. All other parts must be replaced by a qualified gas service person.
PART
Door Gasket
Glass Gasket
Door Glass
Pilot Assembly
Piezzo Lighter
Log Set
Owner's Manual
Venting
The venting system should be periodically inspected
by a qualified agency. If the vent pipe is
disassembled for inspection or repair you must twist
lock each piece in place on re-assembly. In addition
the pipe adaptor (piece that connects to stove) must
be sealed with high temperature (red) silicone. The
flow of combustion and ventilation air must not be
obstructed.
Appliance Area
Keep area around appliance free of combustible
materials, gasoline, and other flammable vapors and
liquids.
DESCRIPTION
White 3/8" dia. fiberglass rope 51" long
Tape Knit Hytex 301B Channel
5 mm Pyroceram 12" x 17"
Thermopile, thermocouple, pilot housing
Igniter button
Front and back logs
This document