Burner And Pilot Checks; Burner On/Off Switch; Gas Control Knob; Hi/Lo Flame Adjust - Echo DIRECT VENT GAS HEATER Installation And Operating Instructions Manual

Table of Contents

Advertisement

ECHO
There are no combustibles placed within 36" of heater or vent pipe or any combustibles that can swing
within 36" of heater such as door drapes, etc.
The location of the main shut off valve is known by everyone in the house (it is usually next to the gas
meter or propane tank). EVERYONE must know where this valve is located.
All necessary permits and installation information have been obtained and the final inspection has been
performed by the local building inspector.
The operation instructions located on the gas valve panel door have been read and understood. A copy of
these instructions can be found in the "Operations" section of this manual.
The operator and pilot igniter have read this manual thoroughly and understand it.

Burner and Pilot Checks

A periodic check of the pilot and burner flames
should be made. Check after the fire has been on for
at least 30 minutes. The pilot flame must cover the
tip of the thermocouple and thermopile probes, if
the pilot flame does not sufficiently cover the
probes it can be adjusted using the pilot adjustment
screw found on the front of the gas valve. The main
burner flame pattern will vary from appliance to
appliance depending on the type of installation and
climatic conditions.

OPERATION

Location of Controls

See Figure 21 for location of controls. Control
functions are outlined below.

Gas Control Knob

This knob is used for starting the pilot and has three
(3) positions: On, Off, and Pilot. The pointer

INSTALLATION CHECKLIST

Check off the following list before proceeding to light the heater.
directly above the knob indicates the position the
knob is in.

Hi/Lo Flame Adjust

This knob controls the burn, either high or low. It is
operated manually by turning the knob. Once in
position, the wall thermostat will turn on the burner
to the position which this knob is set.

Pilot Igniter

This button is used to ignite the pilot. It is pushed
in while the gas control knob is in the Pilot
position. When pressed, it creates a spark at the
pilot, igniting it.

Burner On/Off Switch

This switch turns the burner on after the pilot is lit.
When the wall thermostat is hooked up, this switch
will remain in the "On" position after the pilot is lit.
The wall thermostat will then turn the heater on
automatically when indicated.