2
Getting Started
A. Size of Firebox
See Table 1 in Section 1.B.
B. Tools and Supplies Needed
Tools and supplies normally required for installation:
Pliers
Phillips screwdriver
Tape measure
Crescent wrenches
Gas shutoff valve
Non-corrosive leak check solution
3/4 in. wrench, 7/16 in. wrench
C. Inspect the Appliance and Components
• Remove the contents from the carton. Attached to the
burner are tags identifying the manufacturer name, serial
number, model number (including gas log size), BTU
ratings, gas type, etc.
• Review the attached tags before proceeding. Ensure
that all minimum fireplace dimension requirements are
achieved using Table 1 in Section 1.B. See Figure .1.
Ensure the gas type provided in the fireplace coincide
with the gas type marked on the tag.
Figure 2.1
Measure Firebox
4
• Heatmaster/American Gas Log Outdoor Burner/Hearth Kits • IM-116 • 03/09
CAUTION
Sharp Edges
•
Wear protective gloves
and safety glasses during
installation.
WARNING
Asphyxiation Risk
This appliance produces carbon monoxide
(CO).
•
The free opening areas (in square inches)
of the chimney damper as shown in the
tables must be met.
•
User must make sure damper is locked
open.
•
The installer is responsible to ensure
proper ventilation of flue gases before
appliance is used.
Fire needs to draft properly for safe
operation.
WARNING
Heatmaster/American Gas Log disclaims
any responsibility for, and the warranty will
be voided by, the following actions:
•
Installation and use of any damaged appliance or
vent system component.
•
Modification of the appliance or vent system.
•
Installation other than as instructed by Heatmaster/
American Gas Log.
•
Improper positioning of the gas logs or the glass
door.
•
Installation and/or use of any component part not
approved by Heatmaster/American Gas Log.
Any such action may cause a fire hazard.