Heatmaster G Series Operation And Maintenance Manual

Heatmaster G Series Operation And Maintenance Manual

Advertisement

Quick Links

G
OPERATION AND
MAINTENANCE
MANUAL
EPA CERTIFIED WOOD
BURNING FURNACES
Version 10
UL 2523-2018
CAN/CSA B366.1-2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heatmaster G Series

  • Page 1 OPERATION AND MAINTENANCE MANUAL EPA CERTIFIED WOOD BURNING FURNACES Version 10 UL 2523-2018 CAN/CSA B366.1-2011...
  • Page 2: Table Of Contents

    HeatMaster Furnaces FOR FUTURE REFERENCE Water Treatment Policy ........................x of the G Series outdoor furnace that it is free from defects Inc. always has the right to decide if a part or furnace will be Recommended Operating Levels ......................x...
  • Page 3: Water Treatment And Testing

    Push the by-pass handle towards the back of the furnace TEST PARAMETERS AND WHAT THEY MEAN • Locate your water sample bottle, mailing carton and long as you own your G Series outdoor furnace. Carefully read and slowly crack the door open for at least 20 seconds Conductivity mailing label provided to you by your dealer.
  • Page 4: Furnace Installation Guide

    CLEARANCES TO COMBUSTIBLES Installation should be performed by a qualified installer and must comply with all requirements of the agency having jurisdiction. Whether installing your G SERIES furnace inside a building or Whether installing your G SERIES furnace inside a building or 6”...
  • Page 5: Trench

    Note: Incorrect chimney installation will void the warranty. chimney and draft inducer are especially important at the The chimney on your G Series furnace is a stainless steel end of the heating season to minimize corrosion during chimney. When installing the furnace, the chimney should never the summer months caused by accumulated ash.
  • Page 6: Chimney Installation

    • Maximum 8 ft run from elbow to elbow, but keep as short to obtain a building permit for the installation of this must clear anything within a 10-foot radius by at least 2-feet. located. Your G Series furnace adds to that draw, making it as possible. appliance or the chimney.
  • Page 7: Wiring And Hydronic Lines

    • All wiring must conform to local codes. Pressurized Boiler Systems Your G Series furnace comes factory equipped with a You may require either a water-to-water (tube and shell or plate) • Use an electrical wire (rated and approved) for underground...
  • Page 8: Domestic Hot Water

    However, tube and shell exchangers hold up better when hard water is present. Example of hookup for a forced air furnace and hot water. HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 9: Operating The Furnace

    Typical Moisture Meter on the inner rings. Unseasoned wood has a wet, fresh looking HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 10: Loading The Furnace (Smokeless Loading)

    Handle over center all the way to the front of the furnace to Moisture Meter (Video) and Store (Video) EPA’s Burnwise Program the closed position. https://www.epa.gov/burnwise https://youtu.be/jM2WGgRcnm0 https://youtu.be/yo1--Zrh11s HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 11: Controls And Safety Devices

    Furnace Control This will allow you to check your firebox, fuel and load your Your HeatMasterSS G Series furnace uses a factory furnace without smoke blowing out of the firebox loading door. programmed control to maintain your water temperature by using air damper controls and draft inducer fan.
  • Page 12: How The G Series Gasification Outdoor Furnace Works

    The wood gas mixture that is created in the firebox is then drawn To obtain the high level of performance of your furnace, certain outdoor heating methods and our G Series outdoor furnaces are through the base of the fire along with any ash that would come with maintenance procedures are required periodically.
  • Page 13: Cleaning Your Furnace

    • HeatMasterSS carries a full line of parts for your furnace including pumps, fittings and heat exchangers. For more information on our parts, please contact your local HeatMaster dealer. Tool #1 Tool #2 Refractory Plug Tool #3 HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 14: Troubleshooting

    Check that all doors are closing properly and that door Check filter cartridge for flow blockage (if installed). as necessary. Always replace the burner plug for operation. gasket is completely sealing. HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 15: Electrical Troubleshooting

    24V DC on the red and 115V AC on the black. If convective circulation. inspect the bypass door for smoke leakage. If there is not 24 volts DC check for 115V AC power on HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 16 Loosen level so the float level shows full. that the switch is wired to the correct terminals and that and clean the plates if necessary. HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 17: Editing Control Settings

    Reset the meter by changing the reset option to “on” Colour Copy of Wiring Diagram HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 18 This helps to reduce emissions in idle. HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 19 Please contact your dealer for the latest normal operating temperature. bypass for extended periods of time may overheat the to be reloaded. version available. fanvvvmotor causing premature failure. HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 20: Combustion Tuning Basics

    **IMPORTANT** Changing these parameters can affect the performance and operation of your furnace adversely. Changing operation after making a change, observing the furnace to see these parameters should only be done under the guidance of your Heatmaster dealer. Make small changes at a time and if you’ve made a positive change.
  • Page 21: Home Network Connection

    1B Wireless Connection: This alternate method requires the installation of a wireless access device. This is available as part of the HeatMaster Wireless Access Kit. Please contact your dealer If you are making changes to the o2 setpoint, change by 1% at a for more information.
  • Page 22: Hardwired Connection

    Once you have assigned your furnace on your home network to assign to your HeatMaster furnace. control an IP address you will be able to access the furnace Using a windows PC that is running on your home network, You will need to run and connect a Cat 5 or 6 cable from your from any device with a web browser connected to your network.
  • Page 23: Addressing Your Furnace

    We need displaying date and time as shown to stop the Logo’s program to make above. this IP address change. Select STOP and press the OK button. HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 24: Viewing Your Furnace In A Web Browser

    Bookmark this page in your web browser, allowing you quick access to this page at any time. HeatMaster G Series Furnace Operating Manual HeatMaster G Series Furnace Operating Manual...
  • Page 25 For more information on our parts or to arrange product installation please contact your local HeatMaster dealer. HeatMaster Furnaces Inc. Box158 Winkler, Manitoba, Canada...

Table of Contents