INSTALLATION

• Install the unit on a heat-resistant work surface.
• This appliance should have at least 100mm clearance at the back , as
it has a rear facing flue to enable two appliances to be stacked using
our optional stacking kit. Where it is to be positioned in close proximity
to walls, partitions, kitchen furniture, decorative finishes, etc., it Is
recommended that they be made of non-combustible material, or if not,
be clad with a suitable non-combustible heat insulating material, and
that the closest attention be paid to fire prevention regulations.
• Make sure that the surface is firm and level.
• Inform all users that the surfaces and base will become hot
• For safety regulations the plug or means of disconnection must always
be accessible
Connecting to the electricity supply
ECO8
The unit must be earthed
Check that the voltage of your electricity supply corresponds to the voltage
shown on the serial plate
The product is supplied with a 13 amp plug. If replacing the plug, connect the
terminals as follows:
− Green and yellow wire
− Blue wire
− Brown wire
ECO9
The unit must be earthed
Check that the voltage of your electricity supply corresponds to the voltage
shown on the serial plate
This unit must be connected to the supply by a qualified electrician in
accordance with Health and Safety at Work Acts and other relevant
regulations, standards and codes of practice
A means of disconnecting from the supply must be provided with at least 3mm
contact separation in all poles
IS331 ECN3191
Earth
E
Neutral N
Live
L