Specifi cations
Rated Power Supply .................100 to 240 V AC, 50/60 Hz
Rated Input ...............................0.9- 0.4 A (100-240 V)
Colour System ..........................PAL-type colour system.
Operating Temperature .............41 °F-104 °F (5 °C to 40 °C)
Relative Humidity .....................Max. 80 (%)
Altitude .....................................Max. 2000 (m)
Dimensions ...............................425 (Width) x 375 (Depth) x 133 (Height) (mm)
Weigh .....................................9.8 kg (when 1 HDD is attached)
Recording System ....................Digital recording system
Sampling ............................13.5 MHz
Data Compression .............JPEG2000
Compression Unit ...............Frame, Field
Recording Resolution ...............720 x 576, 720 X 288
Recording Device .....................Hard disk drive (HDD)
Video Input ...............................16 Input BNC-Connectors:
Monitor Output ..........................S-Connector:
Throughout Output ..................16 Output BNC-Connectors: 1.0 V(p-p), 75 ohms.
Audio Input ...............................RCA-Jack:
Audio Output ............................RCA-Jack:
Clock
.....................................±20 seconds/month (when power is supplied, 25 °C)
Timer Program ..........................8 programs-Daily start and stop time for one week x 2 set
Memory Backup .......................Lasts for more than 1 month (when fully charged)
Connectors
External storage terminal ...Serial bus (1-4) (For connecting the recommended optional items only)
Control terminals
Clock adjust Input ........Active:
Clock adjust Output ......Active:
Recording start Input ....Active:
Recording stop Input ....Active:
Emergency Input ..........Active:
Mode out (1-4) .............Active:
Call out +/– ...................Active:
(Photo coupler output) Non active:
Ground terminal
DC 12 V Output ............Max. 350 mA DC (when Main switch and power button is turned on)
Alarm Input (1-16) ........Active:
Alarm Output (1-16) .....Active:
PTZ terminal ................RS-232C terminal
Serial port .....................RS-232C D-SUB 9 pin
RS-485 port ..................RS-485 Input/Output, RJ-11
Communication
LAN ..............................Connector form: RJ-45
DVD-R/RW, CD-R/RW recording format ...........Original format
Accessories ..............................AC power cord (For U.K/for the Continent)
Weight and dimensions shown are approximate.
Design and specifi cations are subject to change without notice.
This unit complies with the European EMC test standard EN50130-4.
1.0 V(p-p), 75 ohms.
Y-Signal:
1.0 V(p-p), 75 ohms.
C-Signal:
0.3 V(p-p), 75 ohms.
2 Output BNC-Connectors: 1.0 V(p-p), 75 ohms.
RCA-jack:
1.0 V(p-p), 75 ohms.
308 mV(rms), 50 k ohms.
308 mV(rms), 1 k ohms.
When terminals are short-circuited or "Low" Level voltage is applied.
Non active:
Open.
"Low" Level Max. Drive current 30 mA DC.
Non active:
Open.
Max. Voltage 24 V DC.
(Clock adjust Output is throughout of Clock adjust Input)
When terminals are short-circuited or "Low" Level voltage is applied.
Non active:
Open.
When terminals are short-circuited or "Low" Level voltage is applied.
Non active:
Open.
When terminals are short-circuited or "Low" Level voltage is applied.
Non active:
Open.
"Low" Level Max. Drive current 30 mA DC.
Non active:
Open.
Max. Voltage 24 V DC.
Short
Max. Drive current 7 mA DC.
Open.
Max. Voltage 24 V DC.
When terminals are short-circuited or "Low" Level voltage is applied.
Non active:
Open.
"Low" Level Max. Drive current 30 mA DC.
Non active:
Open.
Max. Voltage 24 V DC.
RS-422 terminal
Physical interface: 10BASE-T/100BASE-TX
CD
Cable clamping band
Installer's manual (this manual)
User's manual
2
1
2
1
1
Specifi cations
127