Edirol V-Link LVS-800 Owner's Manual
Edirol V-Link LVS-800 Owner's Manual

Edirol V-Link LVS-800 Owner's Manual

Video mix/live switcher remote control
Hide thumbs Also See for V-Link LVS-800:

Advertisement

Quick Links

REMOTE CONTROL

Owner's Manual
This document describes various settings to remotely control the LVS-800 via V-LINK/MIDI and
RS-232C. The LVS-800 can receive remote control commands from Roland's Musical Instruments,
Music Production Devices, Video Presenters (PR series), touch panel devices and computers. The
LVS-800 can also remotely control RSS V-Mixer.
Copyright © 2009 ROLAND CORPORATION
All rights reserved. No part of this publication may be reproduced in any form without the written permission
of ROLAND CORPORATION.
1PS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V-Link LVS-800 and is the answer not in the manual?

Questions and answers

Summary of Contents for Edirol V-Link LVS-800

  • Page 1: Remote Control

    REMOTE CONTROL Owner’s Manual This document describes various settings to remotely control the LVS-800 via V-LINK/MIDI and RS-232C. The LVS-800 can receive remote control commands from Roland’s Musical Instruments, Music Production Devices, Video Presenters (PR series), touch panel devices and computers. The LVS-800 can also remotely control RSS V-Mixer.
  • Page 2: Table Of Contents

    Contents Connecting Peripheral Devices .............3 Connecting V-LINK/MIDI devices ....................3 Connecting Musical Instrument or Music Production Device ..........3 Connecting PR Series Video Presenter ................3 Connecting to a RSS V-Mixer..................... 3 Connecting with RS-232C devices ....................4 Things You Can Do with Remote Control..........5 Control from V-LINK/MIDI devices (slave operation)..............
  • Page 3: Connecting Peripheral Devices

    The LVS-800 can also transmit the remote control commands (master operation). Connect LVS-800’s MIDI OUT/THRU connector with the MIDI IN connector of the V-Mixer. * You must switch MIDI Thru to MIDI Out. Select [Out] in [MIDI Out/Thru Switch] in the LVS-800 MIDI SETUP menu. fig.connect-M400.eps...
  • Page 4: Connecting With Rs-232C Devices

    Connect your RS-232C device (computer, touch panel device, etc.) to the LVS-800’s RS-232C connector. fig.connect-PC.eps Here is the pin assignment of the LVS-800’s RS-232C connector. Since the RS-232C connector is male, use a female plug on your crossover (or “null modem“) cable when connecting from computer or similar RS-232C device.
  • Page 5: Things You Can Do With Remote Control

    The V-LINK feature provides a quick and simple way to establish a link with a Roland musical instrument, music-production device or PR series Video Presenter. If you connect the LVS-800 with a V-LINK compatible device, you do not need to perform detailed setup for remote control.
  • Page 6: Midi Implementation

    MIDI Implementation Model: LVS-800 Version: 1.00 Date: July. 31. 2009 Symbol Item Setting range ------------------------------------------------------------------------------------ MIDI channel 0H-FH(ch.1 - ch.16) Control value 00H-7FH(0 - 127) Switch on and off¶ 00H-3FH(0 - 63):OFF 40H-7FH(64 - 127):ON ------------------------------------------------------------------------------------ 1. MIDI messages received at MIDI IN * If MIDI Thru is ON, MIDI messages received at MIDI IN will be retransmitted without change from MIDI OUT.
  • Page 7: System Realtime Messages

    MIDI Implementation Modulation (controller number 1) General Purpose Controllers 5-8 (controller numbers 80-83) Status 2nd byte 3rd byte Status 2nd byte 3rd byte 50-53FH Breath-type (controller number 2) Portamento Control (controller number 84) Status 2nd byte 3rd byte Status 2nd byte 3rd byte Foot-type (controller number 4) Effect Depth 2-5 (controller numbers 92-95)
  • Page 8: System Exclusive Message

    * If MIDI Thru is ON, MIDI messages received at MIDI IN are re- 51H, 12H, aaH, transmitted without change from MIDI OUT. bbH, ccH, ddH, * If MIDI Thru is ON, message from the LVS-800 itself will not be ..., eeH, sum transmitted. Byte...
  • Page 9 MIDI Implementation Balance (controller number 8) Program Change Status 2nd byte 3rd byte Status 2nd byte pp=program number : 00H - 7FH (prog.1 - prog.128) Panpot (controller number 10) Status 2nd byte 3rd byte * Sent in combination with Bank Select message when an input selection is made.
  • Page 10: Parameter Address Map

    The next byte transmitted is 0CH. For reception, this is ignored if two bytes are not received together. * If --- os shown in the value field, the LVS-800 does not have a corresponding parameter. This will be ignored if received.
  • Page 11: V-Link Master (Model Id=00H 51H)

    Example) If the original data is 028AH, a value of 05H is transmitted as the first byte. A value of 0AH is transmitted as the second byte. * If --- is shown in the value field, the LVS-800 does not have corresponding parameter.
  • Page 12: Appendices

    MIDI Implementation 4. A A A A p p p p p p p p e e e e n n n n d d d d i i i i c c c c e e e e s s s s Examples of MIDI messages <Example 1>...
  • Page 13: Settings Transmitted/Received Using Midi

    The factory default setting is CC#7 (volume). Values are 0–127, corresponding to 0.0 sec - 4.0 sec. MIDI Channel This sets the LVS-800’s MIDI transmission and receiving channel. Panel Preset Assign The factory default setting is 1. This selects number of the Panel Preset.
  • Page 14: Midi Implementation Chart

    MIDI Implementation Chart Date : Jul. 31. 2009 Model LVS-800 Version : 1.00 Function... Transmitted Recognized Remarks Basic Default Changed 1 - 16 1 - 16 Channel Default Mode Message Altered Note : True Voice Number Note ON Velocity Note Off After Key’s...
  • Page 15: Rs-232C Command Reference

    INC : BACKGROUND channel select Devices to LVS-800 stxINC:a; * When transmitting commands to LVS-800 from external device, be • a: channel number. sure that ACK is returned before transmitting the next command. • 0: A/B MIX, 1: channel 6, 2: channel 7.
  • Page 16 • 0-255, 0: 0% - 255: 100%. • Performs PGM output fade with the time specified. • Specifies DSK’s Video Fader position that is moving • ACK is returned from LVS-800 upon proper reception with AUTO button operation. of the command.
  • Page 17 “a“, “b“, “c“ • a: Model Name = LVS-800 • Version • Reserved This is transmitted when LVS-800 receives a VER command. The version information is transmitted in ASCII character strings. XON : Flow Control XOFF : Flow Control XOFF...