changing
the
flashtube
WaRNING HIGH VOltaGe
Do Not touch the Flashtube assembly
For thirty Minutes after Use & after
Disconnecting From Power Supply
1. Ensure that the Ringflash is switched
step
off and disconnected from the mains
supply and wait for thirty minutes
to allow to cool down before touching
/ removing the flashtube.
2. Before removing the flashtube
step
assembly from the Ringflash first
remove the two modelling lamps
next to the trigger wire tab and then
unwind the trigger wire from the
tab as shown in fig. 7. It is
recommended to remove the two
modelling lamps next to the trigger
wire tab to allow more room to when
unwinding the trigger wire and so not
to damage the lamps.
changing
the
flashtube
3. To remove the flashtube assembly
step
hold gently on both sides and pull
away from the Ringflash as shown
in fig. 8. To replace the flashtube
assembly, simply place all four
support legs into the correct fittings
and gently push back in ensuring
all four legs are placed back in
evenly and secured by fully inserting
into the flashtube leg connections.
N.B. Always replace with the correct
flashtube assembly.
fig. 7
modelling
lamp
WaRNING HIGH VOltaGe
Do Not touch the Modelling lmaps
For thirty Minutes after Use & after
Disconnecting From Power Supply
1. Ensure that the Ringflash is switched
step
off and disconnected from the mains
supply and wait for thirty minutes
to allow to cool down before
touching / removing the modelling
lamps.
2. To remove the modelling lamps grip
step
gently between fingers and pull away
slowly from the Ringflash as shown
in fig 9. To replace the modelling
lamps simply align the two legs of
the lamp with the correct fitting and
gently push back in ensuring that the
lamp legs are fully inserted.
fig. 8
replacement
fig. 9