7.Troubleshooting

7-1.Troubleshooting
Note: The basic configurations of the main boards (ie. boards including signal processing ICs) are generally common for all types (the sole difference is whether or not all
functions are incorporated in a single chip).
The following presents the methodology used in determining locations of faults, and of repairing those faults. All faults listed below which are due to blown fuses, soldering
defects, FFC connection defects, and FFC defects must be repaired.
<Fault description>
<Fault diagnosis flow>
(1) Power does not
Are FFCs connecting boards inserted
come ON.
squarely, have FFC patterns peeled?
Is the fuse on the DCST board blown?
Is the card cover detect switch OK?
Is the fuse on the main board blown?
Is soldering of board-to-board connector OK?
Is soldering of the crystal
on the main board OK?
(2) Cannot initialize
(card error, read
Is soldering of card connectors OK?
error, or frame
error).
(3) Recorded image
defective.
(4) Lens cover error.
(1) No image,noisy
image.
from the lens to the main board
(5) Focusing defect.
Is the position of the macro
Are the relative positions of the
46
Check for FFCs connecting boards not inserted
NO
squarely, check for FFC problems, reassemble
and replaced FFC.
YES
NO
Check for a blown fuse on the DCST the board,
and replace the fuse (*1).
YES
NO
Replace the card cover detect switch (*1).
YES
NO
Replace the fuse on the main board (*2).
YES
NO
Re-solder board-to-board connector.
YES
NO
Re-solder crystal on main board (*2).
YES
NO
Re-solder card connector.
Replace card connector.
YES
NO
Is the lens cover open/close
Replace lens cover open/close detect switch.
detect switch OK?
YES
NO
Has the F CABI assembly been
Reassemble/replace F CABI assembly .
assembled correctly?
YES
NO
Is the FFC for the connector
Repair at the defective location.
OK?
YES
NO
Is soldering of IC1 on the
Re-solder if defective. Check lens resolution (*3).
CCD board assembly OK?
YES
NO
Move the macro selector lever to the appropriate
position.
selector lever appropriate?
YES
Reassemble
lens and the macro selector
lever OK?
Is the main board assembly
Replace the macro detector switch (*1).
macro detector switch OK?
FinePix30i(U/E/EG) SERVICE MANUAL
<Repair method>
See after-service technical communication
(GS-01-036).
Replace main board.
Replace main board.
Replace main board.
Replace main board.
Replace the lens assembly.
Replace the lens assembly.
<Cause>
<Remarks>
(*1)
Refer to the service manual
for details of location of
components on DCST board.
(*2)
Refer to the service manual
for details of location of
components on main board.
Soldering defect with CSP_ICs
(eg. image signal processing IC
(VCS), SDRAM_IC, ROM_IC).
Soldering defect with CSP_ICs
(eg. image signal processing IC
(VCS), SDRAM_IC, ROM_IC).
Soldering defect with CSP_ICs
(eg. image signal processing IC
(VCS), SDRAM_IC, ROM_IC).
(*3)
Refer to relevant technical
communication No. GS-
00-050.
CCD board assembly
defective.
Defect in optical system.