10. I
C Adjustment Parameter List (continued)
TC90103 (12/12)
Adjustment
Mode OSD
TC90103
ANT/NTSC/480i
186
Memory Write Horizontal Phase Adjustment
08h -2.37us
187
Memory Write Vertical Start Phase Adjustment
08h -8H
188
Burst Gate Pulse Start Phase Adjustment
00h 0us
[02h: Default] 3.58MHz unit
189
Clamp Pulse Horizontal Adjustment for Ghost
Canceller Tuner
08h -1.185us
[0Dh: Default] 6.75MHz unit
190
Pedestal Detection Pulse Start Phase Adjustment for Horiz
ontal Separation
08h:-2.37us 00h:±0 07h:+2.07us 3.375MHz unit
191
Pedestal Detection Pulse Start Width Adjustment for Horizo
ntal Separation
08h:-2.37us 00h:±0 07h:+2.07us 3.375MHz unit
192
Charge Discharge Pulse Start Phase Adjustment for
Input Clamp
08h:-2.37us 00h:±0 07h:+2.07us 3.375MHz unit
193
Charge Discharge Pulse Start Width Adjustment for
Input Clamp
08h:-2.37us 00h:±0 07h:+2.07us 3.375MHz unit
194
Color Stripe Detection
00h OFF, 01h ON
195
Noise Detection Period Vertical Start Adjustment
NTSC 7H/270H Lines
PAL
196
Read Data Read Order Switch
197
EDTV
00h OFF ED2 Impossible ,
01h ON ID1 Impossible
198
Linear Area Width Setting for ANT(Analog)
Adjustment Item
00h 0us
07h +2.07us
00h 0us
07h +7H
0Fh +4.44us
00h 0us
07h +1.04us
Register Value
H/316H Lines
Register Value
Detection
Adjustment
Range(HEX)
00 0F
00 0F
00 0F
00 0F
00 0F
00 0F
00 0F
00 0F
00 01
00 07
00 07
00 01
00 07
64
DW1U
Initial Data(HEX)
DW1-U
08
08
02
08
08
08
08
08
00
00
00
00
05