Sharp R-3S68 Service Manual page 21

Table of Contents

Advertisement

Re-install
1. Insert tube into filament lead (longer one) of power
transformer.
2. Install the terminal insulator to receptacle of filament
lead (longer one) of power transformer.
3. Rest transformer on the bottom plate right with its primary
terminals toward the oven face plate.
1. Open covers of the terminal insulator by using small flat
type screw driver.
2. Remove the receptacle from the terminal insulator.
3. Now, the terminal insulator is free.
Terminal
insulator
HIGH VOLTAGE RECTIFIER AND HIGH VOLTAGE CAPACITOR REMOVAL
1. CARRY OUT 3D CHECKS.
2. Disconnect the high voltage wire of the high voltage
rectifier assembly from the magnetron.
3. Remove one (1) screw holding capacitor holder to oven
cavity rear plate.
4. Remove one (1) screw holding high voltage rectifier
assembly to capacitor holder.
5. Disconnect rectifier terminal from capacitor.
6. Now, high voltage rectifier assembly is free.
1. CARRY OUT 3D CHECKS.
2. Pushing the lever of positive lock
3. Pull out the positive lock
CAUTION: WHEN YOU (SERVICE ENGINEERS) CON-
NECT THE POSITIVE LOCK
TO THE TERMINALS, CONNECT THE POSI-
®
TIVE LOCK
YOU (SERVICE ENGINEERS).
1. CARRY OUT 3D CHECKS.
2. Disconnect wire leads from panel components.
3. Release one (1) nail holding the control panel assembly
to the oven flange.
4. Remove control panel assembly and slide upward.
5 . Now, individual components can be removed.
NOTE: 1. Before attaching a new key sheet, wipe off
remaining adhesive on the control panel frame
TERMINAL INSULATOR REPLACEMENT
Flat type
screw driver
POSITIVE LOCK
®
connector.
®
connector.
®
CONNECTORS
SO THAT THE LEVER FACE
CONTROL PANEL ASSEMBLY REMOVAL
4. Secure transformer with four screws to bottom plate right.
5. Re-connect wire leads (primary and high voltage) to
power transformer and filament leads of transformer to
magnetron and high voltage capacitor. Refer to
"PICTORIAL DIAGRAM".
6. Re-install outer case and check that oven is operating
properly.
Installation
1. Insert the receptacle into terminal insulator.
2. Close covers of the terminal insulator, as shown illustrated
below.
COVERS
7. Disconnect wire leads from capacitor and remove
capacitor holder.
8. Now, high voltage capacitor is free.
CAUTION: WHEN REPLACING HIGH VOLTAGE
RECTIFIER AND HIGH VOLTAGE CAPACITOR,
GROUND SIDE TERMINAL OF THE HIGH VOLTAGE
RECTIFIER MUST BE SECURED FIRMLY WITH A
GROUNDING SCREW.
®
CONNECTOR REMOVAL
Figure C-2. Positive lock
surfaces completely with a soft cloth soaked in
alcohol.
2. When attaching the key sheet to the control panel
frame, adjust the upper edge and right edge of
the key sheet to the correct position of control
panel frame.
3. Stick the key sheet firmly to the control panel
frame by rubbing with soft cloth not to scratch.
19
RECEPTACLE
Terminal
Positive lock®
connector
1
Push
Lever
2
Pull down
®
connector
R-3S68

Advertisement

Table of Contents
loading