10. Align fuel pump coupler on pump shaft/fan motor.
Slide pump into fan motor. Secure pump with the
three set screws.
11. Test machine (make sure):
q
Blower motor spins
q
Fuel is on
q
Machine has power to it
q
Switch is on
q
Flow of water through machine
q
Thermostat is turned up
q
Flow switch is adjusted properly
12. When machine is operating properly, turn machine
off, tighten front panel, and install hood and 13 self
tapping screws with recess washers.