Appendix Equick Reference Information - Bryant 355MAV Troubleshooting Manual

Series h & i variable speed, two-stage electronic condensing gas furnace
Table of Contents

Advertisement

UNIT SIZE (BTUH)
40,000
60,000
80,000
100,000
120,000
UNIT SIZE (BTUH)
60,000
80,000
100,000
120,000
Flame Sensor Microamperage:
Microamp Range: 0.5 to 6.0 microamps
Typical Reading:
4 to 6 microamps in high heat
Hot Surface Ignitor Reading:
355MAV – Ohm reading of new HSI @ 70°F:
355AAV & 355BAV – Ohm reading of HSI @ 70°F:
The Silicon Nitride igniter in this furnace is not voltage sensitive and will work within the voltage range of 102 to 132 VAC. Hence, there is no voltage
regulation circuits on the furnace control board. A new Silicon Nitride igniter has a normal resistance range of 40 to 70 ohms at room temperature and
is relatively stable over the life of the igniter. The igniter resistance will increase with temperatures above room temperature.
Gas Valve Ohm Readings:
M to C: Resistance cannot be measured with an ohm meter because there is a bridge rectifier in the gas valve circuit.
Hi to C: Resistance cannot be measured with an ohm meter because there is a bridge rectifier in the gas valve circuit.
Power Choke (Inductor):
Run unit in cooling mode, measure motor amp draw before power choke. Then rerun unit in cooling mode, but this time measure amp draw without
power choke in line. The amp draw should be higher without power choke. Some ammeters will register a lower amp draw (look for a change in
amperage).
APPENDIX E
QUICK REFERENCE INFORMATION
355MAV & 355AAV PRESSURE SWITCH MAKE/BREAK POINTS
HIGH-HEAT PRESSURE SWITCH
Make Point
1.81 in.wc max
1.63 in. wc +/- 0.05
1.81 in.wc max
1.63 in. wc +/- 0.05
355BAV PRESSURE SWITCH MAKE/BREAK POINTS
HIGH-HEAT PRESSURE SWITCH
Make Point
1.81 in.wc max
1.63 in. wc +/- 0.05
40 to 90 ohms
(resistance will go up with HSI life and exceed the new HSI resistance over time).
40 to 70 ohms
Break Point
0.75 in. wc max
0.95 in. wc max
Break Point
0.86 in. wc max
0.91 in. wc max
0.95 in. wc max
0.86 in. wc max
(resistance will remain relatively stable over the life of the igniter).
- 40 -
LOW-HEAT PRESSURE SWITCH
Make Point
Break Point
0.60 in. wc +/- 0.05
0.80 in. wc +/- 0.05
LOW-HEAT PRESSURE SWITCH
Make Point
Break Point
0.71 in. wc +/- 0.05
0.76 in. wc +/- 0.05
0.81 in. wc +/- 0.05
0.71 in. wc +/- 0.05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

355aav355bav

Table of Contents