Trap Switch Location (Media Receiver)
Outline and Notes
For video data transmission from the Media Receiver to the PDP-436U and PDP-506U-series Plasma Displays, digital signals
are used. Therefore, this unit adopts the HDCP (High-bandwidth Digital Content Protection) system for copyright protection.
This unit is also provided with a detection switch (TRAP switch) that will prohibit the unit from being turned on again "if the
upper plate of the unit is accidentally opened," in order to prevent the panel technology from being leaked out.
The TRAP switch is disabled while the unit is turned off.
When performing internal diagnosis of the PDP, fix the switch to the OFF position using adhesive tape before turning on the
unit. After servicing, be sure to remove the adhesive tape.
To Release an Activated Trap Switch:
1. Enter Factory Service mode
2. Select initialize mode
3. Hold down Display Key on Remote
for 5 seconds.