Page 1
4._m "=" canresultinserious i njury o rproperty damage. NOTICETO INSTALLER: LEAVE THESEINSTRUCTIONS W ITHTHEAPPUANCE. NOTICETO CONSUMER: R ETAIN THESEINSTRUCTIONS FORFUTUREREFERENCE. SPECIAL WARNING: I mproper GAS coorops [ I "JENN-AIR JGC7430 AND JGC7536 \\ _\ . Clearance I _._A9"_ ,_'-_',,.,,;,=----,i._ll. installation,...
LOCATION OFYOUR JENN-AIR A PPUANCE Locate thisappliance away fromcombustible materials s uchas window curtains a ndcombustible walldecorations, Minimum horizontal clearance b etween theedgeoftheappliance and combustible construction extending from thecooking surface t o18 _(45.72 cm)above thecooking s urface i s 1" (2.54cm)atrear 4"...
N ever t estforgas leaks with an open flame. ILLUSTRATIVE GAS SUPPLY PIPING (NO OTHER APPLIANCE BELOW COOKTOP) I I _ I_, _ to theseinstructions ELBOW APPLIANCE TOGASSUPPLY...
Page 4
S. SUPPLY PIPING BELOW 30" COOKTOP) =_'_ER eox (Rz,_ oF _a I _"¢" t_="_ [ lr,.N.p.,. ] ALL _ PE ao_xrs L- _ .,%._...
(either gassupply o rtheappliance m anifold) soas tobe physically s tationary. Seaillustrations below: ILLUSTRATIVE ALTERNATIVE PIPING e.-..- jCalt NOAPPL.JANOE THIS COOKTOP MOUI/11_D BELOW WALL OVEN MOUNTED _ _-_NPTP_ IN CABINETRY BELOW...
ELECTRICAL WIRING INFORMATION This appliance isequipped w itha grounded type power c ord. Agrounded outlet must b eprovided. Itisrecommended, forconvenience, located (with reference tofigure 6) asinAor8, below: A. If noother a ppliance i stobeinstalled below thisappliance: within _ ther theshaded a reaorthecross hatched a reashown infigure 6. B.
Page 7
CONVERTING APPLIANCE FORUSE WITH LP GAS WARNING Propane c onversion isto beperformed bya JENN-AIR A UTHORIZED SERVICER(or otherqualified agency)in accordance withthe manufacturer's instructions and all codes andrequirements of the authority having j urisdiction. Failure t ofollow instructions serious injury o rproperty damage. Thequalified a gency performing this work assumes responsibility forthis conversion.
B. Invert mp In appliance presaure regulator (See figures 10and11.) Withtheappliance i nstalled, theapplience r egulator should belocated asshown in figure 3or4.Identify thetypeof appliance regulator onthe unitandfollow theinstructions intheappropriate CONVERSION OF MAX1TROLAPPLIANCE PRESSURE REGULATOR CO_IVERTE APPLY SI_'A_ fJqqPTO RB_OVE ¢/# PiN ,j.
Page 9
TOCONVERT A PPLIANCE FORUSEWITH NATURAL G AS WARNING Electrical power and gas must be turned off p rior to conversion. If this appliance hasbeenconverted forusewithLPgas,eachofthe following m odifications must be performed t oconvert t heunitbackto natural gas. A. Replace allorificespuds Perform Steps 1 through 4 onpage 5.
BURNER IGNITION ANDAUTO-REIGNITION Thisappliance is equipped f orelectronic a uto-raignition spark igniter l ocated attherearofeachburner. Theburners aredesigned tolight a tanyvaJve rotation t hatadmitssufficient ges flow tosupport aflame andtoautomatically relight f ollowing a lessofflame duetoa draftorother adverse condition. Thisfeatureis provided as a convenience andis not intended asa safetyfeature.