LTC 8850 | Instruction Manual | Allegiant Server
Dwell Time – If a monitor has multiple alarm videos,
the dwell time specifies how long a monitor will
display a particular alarm video before switching to the
next one, unless its alarm switcher is stopped. This
time may be from 1 to 60 seconds. To specify a dwell
time, move the cursor to the appropriate field and
enter the desired value.
Relay Action – This field determines how relays in an
Allegiant Alarm Interface accessory unit are activated
when a group responds to an alarm. If relay activation
is set to number 1, relay number 1 will be activated
whenever any monitor in the group is displaying alarm
video. If relay activation is set to follow monitor, each
monitor in the group that is displaying alarm video
will activate its own relay (monitor 1 will activate relay
1; monitor 2 relay 2; and so on). This relay will remain
active as long as the monitor is displaying alarm video.
Acknowledge Keyboard List – This list controls
which Allegiant keyboards are alerted and allowed to
acknowledge alarms for the group. This only applies if
the alarm acknowledge is enabled.
Figure 74 Alarm Normal Monitors Configuration Table
Bosch Security Systems | 02 April 2004
Alarm Normal Monitors Table
The monitor table displays some of the same
information as the group table, but organized by the
monitor number instead of the group number. This
table provides a simplified display suitable for review
and editing of alarm monitor configurations.
Group - Used to assign a monitor to a particular
Alarm group.
Arm - Enables or disables all alarms for the monitor.
Type - Selects between Step and Review via a pull
down menu.
Figure 75 Alarm Normal Alarms Configuration Table
Alarm Normal Alarms Table
Icon – This column is not shown when the Allegiant
server runs in the stand-alone mode. When it is
accessed within the GUI, this column provides a
description of the icon representing this device in the
map. Right-clicking in this column will bring up the
icon customization dialog and will allow the user to
jump to its location in the map. This cell is blank for
devices that do not have icons in the map.
ID Enable - If ID Enable is checked, the monitor
overlay will display the alarm ID text option in place
of the camera title while alarms are active.
ID Text – The alarm ID Text is a 16 character title
that may be displayed in place of the camera title
while the alarm is active. Special characters can be
entered in the same manner as for the camera titles.