3 Avoid installation where there is a lot of dust or vibrations.
If dust enters the machine, it may degrade copy quality and cause
malfunctions.
4 Avoid installation on an unstable surface.
To assure the proper operations, install on a level surface.
5 Install in a well ventilated place.
6 Avoid installation where there is inflammable gases or am-
monium gases.
Installation near a diazonium copier may degrade copy quality and
cause malfunctions.
7 Install near a power outlet.

(2) Space around the machine

Allow a space of about 15 cm (6 inches) between the rear side of the
machine and the wall for ventilation of the cooling fan. Also allow
sufficient space around the machine for operations.

(3) Installing table

Use a level (UKOGM0054CSZZ) to install the machine horizontal-
ly.
(Allowable tilt: 5 mm between the front and rear frames)
(Note) If the machine is not installed horizontally, toner density con-
trol may not function properly. This may result in poor copy
quality.

(4) Power source

1 The power source should be the rated voltage ±10% with the
capacity corresponding to the max. power consumption.
2 Do not use an extension cord, or operate any other equipment
from the same wall outlet.

(5) Grounding

To avoid electrical hazard, use the properly grounded wall outlet only.
(Carrying the machine)
When carrying the machine, remove the copy tray and hold the dent
portions on the bottom.
4 – 2