Pin No.
Port
Signal name
56
P04
SMG
57
P03
SPPD
58
P02
KEY2
59
P01
KEY1
60
P00
KEY0
61
P87
OP-DATA
62
P86
NC
63
P85
OP-CLK
64
P84
OP-LATCH
65
P83
UN-DATA
66
P82
NC
67
P81
UN-CLK
68
P80
UN-LATCH
69
Vcc
Vcc
70
AVcc
AVcc
71
V
V
REF
REF
72
AV
AV
SS
SS
73
Vss
Vss
74
P77
ANS
75
P76
MBT
76
P75
CLV
77
P74
RTH
78
P73
79
P72
80
P71
TCSA
(3) Start/stop control circuit
1 General
The circuit senses ON/OFF state of the power source to control
start/stop of the circuits.
The DC power section supplies power voltages (V
VC=+10V, VD1=5V, VD2=5V).
After the power voltage reaches the specified level, the circuit opera-
tion is started. Before the power voltage falls below the specified
level, the circuit operation is stopped, preventing against malfunc-
tions.
5V2
IC113
1
VCC
2
5
NC
/RESET
4
3
CAP
GND
C134
22000PF
M51953BL
C106
0.1uF
IN/OUT
H/L
OUT
H
Transport motor gain signal
IN
H
Paper entry detecting signal
IN
L
Operation PWB key input signal
IN
L
Operation PWB key input signal
IN
L
Operation PWB key input signal
OUT
Serial data output to operation PWB
(NC)
OUT
Data output clock signal to operation PWB
OUT
Data latch signal to operation PWB
OUT
Serial data output to lower unit PWB
(NC)
OUT
Data output clock signal to lower unit PWB
OUT
Data latch signal to lower unit PWB
Power (5V)
Analog/Digital convertor reference power voltage
Analog/Digital convertor reference voltage input
Analog/Digital convertor ground pin
Power (GND)
IN
Analog input signal (SPF sensor input)
IN
Analog input signal (Main PWB destination setting)
IN
Analog input signal (Copy lamp control)
IN
Analog input signal (Fusing thermistor)
Not used
Not used
IN
Analog input signal (Toner density sensor)
=+32V, VB=+24V,
H
RESET
5V2
28
CPU
(IC110)
R145
2.4kJ
RESET1
C135
22000PF
RESET2
Description