Setup - Graco 231–034 Instructions And Parts List

Series d, series b airless paint sprayer 3000 psi (210 bar) maximum working pressure
Table of Contents

Advertisement

WARNING
Follow these precautions to reduce the risk of a
serious injury from static sparking, fluid injection, or
rupturing the hose or the gun
All hoses must be electrically conductive.
The gun must have a tip guard.
Each part must be rated for at least 3000 psi
(210 bar) Maximum Working Pressure.
CAUTION
To avoid damaging the pressure control, which may
result in poor equipment performance and compo-
nent damage, follow these precautions:
Always use grounded, flexible spray hose at
least 50 feet (25 meter) long.
Never use a wire braid hose as it is too rigid to
act as a pulsation dampener.
Never install any shutoff device between the
filter (66) and the main hose (100). See Fig. 2.
Always use the main filter–outlet for one gun
operation. Never plug this outlet.
WARNING
Proper electrical grounding is essential to reduce
the risk of a fire or a explosion. A fire or explosion
can cause a serious injury and property damage.
Read the warning section, FIRE OR EXPLOSION
HAZARD, on page 5 for more detailed grounding
instructions.

Setup

NOTE: Refer to Fig. 2 while following this procedure.
1. Fill the packing nut until it is 1/3 full with Graco
Throat Seal Liquid (TSL).
2. Connect the gun, the 3 foot (0.9 meter) hose and
the 50 foot (25.2 meter) hose. Screw the assembly
onto the outlet nipple. Don't use thread sealant
and don't install the spray tip yet!
3. Follow this step to connect a second hose and
gun. Unscrew the cap (72) from the optional outlet.
Use a hose and a gun which are equivalent to the
hoses supplied with the sprayer. Assemble the
hoses and the gun, and then connect the hose to
the optional outlet.
4. Check the electrical service.
a. The electrical requirements are 120 volt, 60 Hz
AC, 15 Amp (minimum).
b. Use a grounded electrical outlet which is
located at least 20 feet (6 meter) from the
spray area.
c. Do not remove the grounding prong of the
power cord and do not use an adapter.
d. The specificiations for the extension cord are
15 amps, 3 wires, grounding–type. Long
extension cords affect the sprayer perfor-
mance.