Booster Applications - Bosch C1210ES Applications Manual

Bosch greentherm & therm tankless water heaters
Table of Contents

Advertisement

Applications Manual

11.1 Booster applications

11.1.1 Solar DHW system with gas tankless water heater
booster
The tankless water heater only runs when solar water
needs a boost. See applicable models listed in the figure
below.
f
Thermostatic valve 1 ensures that warm solar water
bypasses the water heater and directs cooler water
through the appliance when boosting is needed.
f
Thermostatic valve 2 acts as a tempering valve that
brings potentially hot water temperatures down to a
level that is safe for the inhabitants
Applicable models: Bosch 830 ES, 940 ES, 940 ESO,
C 950 ES, C 1050 ES, C 1210 ES.
Bosch Thermotechnology Corp.
THERM/GREENTHERM Tankless Water Heaters | 27
System parameters:
f
Honeywell AM101 Thermostatic Valves required for
proper operation;
f
Remove check valves from Thermostatic Valve 1 as it is
used as a diverter valve;
f
Thermostatic Valve 2 is a tempering valve;
f
Recommended setpoint 120°F for both Valves;
f
Set tankless water heater temperature to 140° F
Data subject to change