Maintenance Instructions; Pump Maintenance - Ramteq BVE Series Operator's Manual

Electric motor/ diesel fired
Table of Contents

Advertisement

O
'
M
peratOr
s
anual
MAInTEnAncE PREcAuTIOns
Do not permit acidic, caustic or abrasive fluids to be pumped through system.
 Periodically clean detergent inlet screen. This will ensure proper flow of water to the pump.
 High mineral content in water may adversely affect your machine and may require the use of a water softener
to ensure proper operation.
 NEVER run the pump dry under any circumtances. Doing so will cause exteme damage to the pump.
W ARNING
hEAT EXchAnGER cOIl MAInTEnAncE
Hard water conditions may eventually cause clogging in the heat exchanger coil if left unattended.
Scale deposits will compromise the heating efficiency and produce an unsafe condition over time.
It may be necessary to descale coil.
Scale buildup from certain detergents may eventually clog up the heat exchanger coil causing an
unsafe condition. Use only recommended detergents for better cleaning efficiency.
Black carbon deposits that collect on the outside wall of the heat exchanger coil may be a result of
using a poor grade of fuel or improper burner operation. Heating fuel should be void of water and
sediments to eliminate the possibility of sooting and compromising the efficiency of the coil.
MOvInG, sTORAGE
Place machine in covered area when not in use to protect from elements.Protect machine from
freezing in cold temperatures by storing in a heated location.
WInTERIZInG
Non-float Tank Machines: To protect the machine from freezing temperatures while
storing or transporting, connect short length of garden hose (approximately 3 ft.) to
water inlet connection on machine. Remove the pressure nozzle from the wand and
insert the short garden hose end into a container of antifreeze. Place the wand into the
antifreeze container and start engine running machine until antifreeze appears from the
end of the wand. Turn engine "OFF" and replace pressure nozzle. Coil up hose and
move machine to storage area.
Float Tank Machines: Pour antifreeze into float tank and remove water nozzle from end
of wand and carefully insert into opening of float tank. Start machine and run until
antifreeze water mixture has circulated throughout the machine returning back to the
float tank.

PuMP MAInTEnAncE

Fill crankcase to dot on oil gauge window per specifications with the specific oil created by the pump
manufacturer (i.e. General Pump Oil). Ensure the right oil for specific pump as it may vary.
Change oil after 40 Hour Break-in Period.
Change oil every Three Months or at 500 Hour Intervals thereafter.
RAMTEQ
®
14275 northwest freeway

Maintenance Instructions

FAIluRE TO MAInTAIn hEAT EXchAnGER cOIl MAy
REsulT In A sTEAM EXPlOsIOn WhIch MAy cAusE
sERIOus InjuRy OR dEATh.
houston, tX 77040
phone: 713.983.6000
faX: 713.983.6405
300-00002-01 11/05