Summary of Contents for Synthes Universal Battery Charger II

  • Page 1 Universal Battery Charger II. Instructions for Use This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation...
  • Page 3: Table Of Contents

    – Battery Power Line and Colibri / Small Battery Drive batteries – Battery Power Line II and Colibri II / Small Battery Drive II batteries – Trauma Recon System power module Storing Batteries Slot Covers Set Universal Battery Charger II Instructions for Use DePuy Synthes...
  • Page 4 – Batteries for Colibri / Small Battery Drive – Battery for Colibri II / Small Battery Drive II Explanation of Symbols Used Symbols for Operating the Charger Symbols on the Charger Ordering Information DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 5: Universal Battery Charger Ii

    Introduction General Information Intended use The Universal Battery Charger II (05.001.204), referred to henceforth as the charger or device, allows the following Synthes batteries to be automatically charged and manually checked: System Handpieces Battery / Power Module Battery Power Line 530.605...
  • Page 6: Safety Precautions

    Before operating the device, check that it is in sound condi- tion and is working properly. If it is not in perfect working order, contact the Synthes representative. Do not use a damaged or faulty device. DePuy Synthes Universal Battery Charger II...
  • Page 7: Scope Of Delivery

    Precautions: – Only use the Synthes Universal Battery Charger II (05.001.204) to charge the batteries. Using a charger that does not originate from Synthes can damage the battery. 2.5 m – Do not open device. Risk of fatal injury due to electric shock! –...
  • Page 8: Front View

    3 ON/OFF display 4 Control display for each charging bay 5 Ventilation holes Rear view 6 Ventilation holes 7 Power switch 8 Fuses: 2 5 AT / 250 V 9 Power cord connection DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 9: Starting The System

    (fig. 3) before the battery is inserted, this charger bay is faulty. In this case, batteries can still be charged in the other charger bays, but it is recommended that the device be sent to the local Synthes representative for repairs. Fig. 1 Precautions: –...
  • Page 10: Charging The Battery

    1 Battery Power Line and Battery Power Line II batteries (530.620, 530.630) 2 Trauma Recon System Power Module (05.001.202) 3 Colibri / SBD and Colibri II / SBD II batteries (532.003, 532.033, 532.103) Fig. 1 DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 11: Charging The Battery

    – Do not insert any objects other than batteries into the charger, as the contacts may otherwise be damaged. Universal Battery Charger II Instructions for Use DePuy Synthes...
  • Page 12: Temperature Monitoring

    – Do not charge mechanically damaged batteries in the charger. – Only charge batteries authorized for the device (see page 32 ff). – Only use fully charged batteries to avoid delays during surgery. DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 13: Checking And Refreshing Batteries

    2 seconds (fig. 1) until the yellow display light lights up (fig. 2). The device then carries out the process. The yellow display lights up throughout this time. Universal Battery Charger II Instructions for Use DePuy Synthes...
  • Page 14 Only then is the battery status clearly assessed. – The process is interrupted if there is a power cut or a switch to the emergency power supply and will then have Fig. 4 to be restarted. DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 15 2 seconds (fig. 5) until the yellow display light lights up (fig. 6). The device then carries out the process. The yellow display lights up throughout this time. Fig. 6 Universal Battery Charger II Instructions for Use DePuy Synthes...
  • Page 16 Only then is the battery status clearly assessed. – The process is interrupted if there is a power cut or a switch to the emergency power supply and will then have Fig. 8 to be restarted. DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 17: Trauma Recon System Power Module

    – If the check is not carried out within the next 3 charging cycles, the charger starts this process automatically. The yellow display lights up (fig. 11). – It takes around 4 hours to check the power module. Fig. 11 Universal Battery Charger II Instructions for Use DePuy Synthes...
  • Page 18: Storing Batteries

    A partial charge may not be sufficient for the intended use. – Unusable or faulty batteries / power modules should not be used. They should be disposed of (see section “Disposal” on page 20). DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 19: Slot Covers Set

    Charger II because it covers the unused slots of the charger (fig. 2). Therefore, it prevents to insert the appropriate bat- tery or power module into the wrong slot. Fig. 1 Fig. 2 Universal Battery Charger II Instructions for Use DePuy Synthes...
  • Page 20 Whenever it is cleaned the device should be checked to ensure it is working properly and is not damaged. Maintenance of the device is not required. If there are any faults, please send the device to a Synthes representative (see next section). Precautions: –...
  • Page 21 To prevent damage during shipping use the original packag- ing to return devices back to Synthes. If this is not possible, please contact the Synthes representative. Users or third parties should not carry out repairs themselves.
  • Page 22 Please send devices that are no longer used to the local Synthes representative. This ensures that they are disposed of in accordance with the national application of the respective directive. The charger may not be disposed of with house- hold waste.
  • Page 23 Check firmware version on the sticker, which is visible on the underside of the charger and compare with the mini- mum required firmware listed on page 25. Send the charger to Synthes re presentative for a software update. Universal Battery Charger II Instructions for Use...
  • Page 24 Charger bay is faulty. Use another free charger bay. Send Red display lights up when the the charger to the Synthes affiliate for charger is switched on before the bat- repairs as soon as possible. teries / power modules are inserted.
  • Page 25 Power Tool or attachment is sluggish, Send Power Tool and attachments to i.e. as a result of insufficient mainte- Synthes representative to be checked. nance. Battery / power module is visibly Battery / power module was exposed Replace battery / power module.
  • Page 26: Device Specifications

    I, EN/IEC 60601-1 (2005+Corr:07) Protection type by casing IPX0, EN/IEC 60601-1 (2005+Corr:07) Fuses 2 5 AT / 250 V Operating mode Continuous operating mode Sterilization Device must not be sterilized Subject to technical modifications DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 27: Minimum Required Firmware Version Of Ubc

    In order that the different battery types can be recognized and charged by UBC II the correct Firmware version is re- quired. The table below outlines the requirements for each battery type. If required, send the charger to a Synthes representative for a firmware update. System...
  • Page 28: Environmental Conditions

    0 – 3000 m 0 – 5000 m – Precaution: The device is not suitable for use in the pres- ence of a flammable anesthetics mixture with air or oxygen or with nitrous oxide. DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 29: Applicable Standards

    Technical Data Applicable Standards The device meets the following standards: EN/IEC 60601-1 2nd Edition Universal Battery Charger II With respect to electrical shock, fire and mechanical hazards only in accordance with UL 60601-1/CAN/CSA C22.2 No. 601.1 10PB IEC 60601-1-2 IEC 60601-1-4...
  • Page 30: Electromagnetic Compatibility

    The Synthes Universal Battery Charger II is intended for use in the electromagnetic environment specified below. The customer or the user of the Synthes Universal Battery Charger II should assure that it is used in such an environment. Emission tests Compliance Electromagnetic environment –...
  • Page 31: En / Iec 60601-1-2, Clause

    The Synthes Universal Battery Charger II is intended for use in the electromagnetic environment specified below. The customer or the user of the Synthes Universal Battery Charger II should assure that it is used in such an environment. Immunity test...
  • Page 32 TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Synthes Universal Battery Charger II is used exceeds the applicable RF compliance level above, the Synthes Universal Battery Charger II should be observed to verify normal operation.
  • Page 33 Synthes Universal Battery Charger II The Synthes Universal Battery Charger II is intended for use in the electromagnetic environment in which radiated RF distur- bances are controlled. The customer or the user of the Synthes Universal Battery Charger II can help prevent electromagnetic...
  • Page 34: Permissible Battery Types

    Power module for Trauma Recon System Art. no. 05.001.202 Operating voltage (rated) 25.2 V Battery capacity 1.2 Ah / 30.24 Wh Battery Li-Ion Typical charging time <60 min Subject to technical modifications DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 35: Batteries For Colibri / Small Battery Drive

    Typical charging time <60 min Precaution: The battery for the Power Drive (530.200) cannot be charged with the UBC II. Please use the UBC item number 530.600 or 530.601. Subject to technical modifications Universal Battery Charger II Instructions for Use DePuy Synthes...
  • Page 36: Symbols For Operating The Charger

    Battery Power Line and Battery Power Line II batteries (530.620, 530.630) Symbol for Trauma Recon System power module (05.001.202) Symbol for Colibri / SBD and Colibri II / SBD II batteries (532.003, 532.033, 532.103) DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 37: Symbols On The Charger

    Temperature (see page 26) Date of manufacture Relative humidity (see page 26) Universal Battery Charger II With respect to electrical shock, fire and mechani- cal hazards only in accordance with Atmospheric pressure UL 60601-1/CAN/CSA C22.2 No. 601.1 (see page 26)
  • Page 38 Power Cord, three-pole, China 05.001.145 Power Cord, three-pole, Japan 05.001.146 Power Cord, three-pole, Argentina 05.001.147 Power Cord, three-pole, Israel Slot Covers Set 05.001.228 Slot Covers Set for Universal Battery Charger II DePuy Synthes Universal Battery Charger II Instructions for Use...
  • Page 40 Ö036.000.500öAE|ä Synthes GmbH This publication is not intended for distribution in the USA. Eimattstrasse 3 CH-4436 Oberdorf All technique guides are available as PDF files at 0123 www.synthes.com www.synthes.com/lit...