Sign In
Upload
Manuals
Brands
Thermo Scientific Manuals
Measuring Instruments
Orion Star A216
Thermo Scientific Orion Star A216 Manuals
Manuals and User Guides for Thermo Scientific Orion Star A216. We have
2
Thermo Scientific Orion Star A216 manuals available for free PDF download: Manual, Reference Manual
Thermo Scientific Orion Star A216 Manual (110 pages)
Electrochemistry Benchtop Meters
Brand:
Thermo Scientific
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
3
Chapter 1
6
Meter Introduction
6
Meter Overview
6
Packing List
7
Intended Use
7
Chapter 2
8
Meter Basics
8
Using the Universal Power Adapter
8
Installing Batteries (Optional Power Source)
9
Attaching the Electrode Stand and Holder
10
Using the Electrode Holder
11
Meter Connections
12
Meter Keypad
14
Function Keys
15
Meter Display
16
Measurement Display Icons
18
Ph Electrode Condition Icon
18
Meter Models and Measurement Capabilities
19
Meter Maintenance
19
Chapter 3
20
Meter Setup Menus
20
Main Setup Menu
20
General Setup Menu Navigation
20
Channel-Specific Method, Mode and Temperature Menus
24
Method Menu
25
Mode and Settings Menu
28
Temperature Menu
41
Instrument Settings Setup Menu
45
Log View Menu
46
Data Log
46
Calibration Log
47
Diagnostics Menu
48
Meter Self Test Procedure
48
Electrode Stability Test Procedure
49
Chapter 4
50
Using the Ph or Ph/Ise Channel
50
Meter and Electrode Preparation
50
Ph Calibration Procedure
51
Ph Calibration Editing
52
ORP Calibration Procedure (Relative MV Mode)
53
ORP Calibration Procedure (E Units)
54
ISE Calibration Procedure
55
ISE Calibration Editing
56
Measurement Procedure
57
Chapter 5
58
Using the Conductivity Channel
58
Meter and Sensor Preparation
58
Conductivity Calibration Procedure
59
Conductivity Calibration Editing
60
Alternative Certified Cell Constant Entry Calibration Procedure
60
Conductivity Standards Vs. Temperature Table
61
Conductivity Meter Verification Procedure
62
Measurement Procedure
63
Chapter 6
64
Using the DO/RDO Channel
64
Meter and Sensor Preparation
64
Dissolved Oxygen Calibration Procedure
65
Air (Water-Saturated Air) Calibration
66
Water (Air-Saturated Water) Calibration
66
Manual (Winkler) Calibration
67
Set Zero Calibration
68
Measurement Procedure
69
Chapter 7
70
Data Transfer and Software Updates
70
Data Storage and Transfer Settings
70
Measurement Read Type Setting
70
Data Log Setting
71
Export Data Settings
72
Printer Compatibility and Requirements
74
Computer Compatibility and Requirements
75
Using the USB-To-Serial Computer Cable
76
Using the USB Computer Cable
78
Orion Star Com Communication Software
81
Meter Interfacing with Other Computer Programs
82
Star A200-A300 Meter Remote Control Protocols
83
Meter Software Upgrade Procedure
90
Chapter 8
94
Customer Services
94
Troubleshooting Tips
95
Meter Factory Reset Procedure
96
Meter User Reset Procedure
96
Notice of Compliance
97
WEEE Compliance
97
Declaration of Conformity
98
Meter Specifications
99
Ordering Information
106
Meter Accessories, Electrodes and Solutions
108
Advertisement
Thermo Scientific Orion Star A216 Reference Manual (61 pages)
pH/RDO/DO Meters
Brand:
Thermo Scientific
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
3
Chapter 1 Introduction
6
Chapter 2 Meter Overview
8
Meter Connections and Inputs
8
Power Source
8
Electrodes and Other Connections
9
Connecting Electrode the Benchtop Meter
10
Meter Display
11
Meter Keypad
12
Meter Maintenance
13
Chapter 3 Meter Setup
14
Navigating the Setup Menu
14
Setup Menu Overview
14
Ph Channel Menu
15
DO/RDO Channel Menu
17
Settings Menu
19
View Log Menu
20
Diagnostics Menu
20
Chapter 4 Ph, Rmv and ORP Calibration
22
Ph Calibration
22
Calibration Editing
23
Rmv Calibration
23
ORP Calibration
24
Chapter 5 RDO/DO Calibration
26
Air Dissolved Oxygen Calibration
26
Water Dissolved Oxygen Calibration
27
Manual Dissolved Oxygen Calibration
28
Set Zero Dissolved Oxygen Calibration
29
Chapter 6 Temperature Calibration
30
Chapter 7 Measurement
32
Chapter 8 Methods
34
Saving the Current Meter Settings as a New Method
34
Loading an Existing Method
34
Editing, Copying or Deleting an Existing Method
35
Chapter 9 Data Storage and Retrieval
36
Data Storage Settings
36
Read Type Selection
36
Computer and Printer Export Settings
37
Data Log Settings
37
Viewing the Calibration Log and Data Log
38
Viewing the Calibration Log
38
Viewing the Data Log
38
Exporting the Data Log to a Computer or Printer
39
Clearing the Data Log
40
Interfacing a Printer
41
Interfacing a Computer
41
Chapter 10 Customer Services
42
Meter Errors and Recommended Actions
42
Meter Self Test and Checkout
43
Meter Self Test
43
Meter Checkout (Ph)
43
Electrode Stability Test
44
Meter Factory Reset
44
Meter User Reset
45
About Meter
45
Assistance
45
Warranty and Registration
45
Ordering Information
46
Chapter 11 Meter Compliance
50
Notice of Compliance
50
WEEE Compliance
50
Declaration of Conformity
51
Meter Specifications
52
Appendix 1 Advanced Meter Features
56
Automatic Ph Buffer Recognition Feature
56
Testing a Ph Electrode for Automatic Buffer Recognition
56
Electrode Condition Icon
57
Multipoint Calibration Curve Feature
58
Dissolved Oxygen Barometric Pressure Compensation
58
Dissolved Oxygen Salinity Correction
59
Advertisement
Related Products
Thermo Scientific Orion Star A214
Thermo Scientific Star A222
Thermo Scientific Orion Star A212
Thermo Scientific Star A221
Thermo Scientific Orion Star A211
Thermo Scientific Orion Star A213
Thermo Scientific Star A223
Thermo Scientific Orion Star A215
Thermo Scientific Orion Star A210 Series
Thermo Scientific Orion Star A220 Series
Thermo Scientific Categories
Laboratory Equipment
Measuring Instruments
Freezer
Accessories
Refrigerator
More Thermo Scientific Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL