Page 1
AVO410 Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter User manual Bedienungsanleitung Manuel utilisateur Guía del usuario Gebruikershandleiding...
Page 2
SAFETY WARNINGS Safety warnings must be read and understood before instrument is used. The following safety information must be observed to insure maximum personal safety during the operation of this meter: Do not use in wet environments. ■ Measurements beyond the maximum selected range must not be attempted. ■...
Page 3
The crossed out wheeled bin placed on the Megger products is a reminder not to dispose of the product at the end of its product life with general waste. Megger is registered in the UK as a Producer of Electrical and Electronic Equipment. The Registration number is WEE/HE0146QT. BATTERIES Should the display fail to illuminate then change the battery.
The AVO410 is aimed at providing electricians with a rugged, easy to use multimeter for field use. Functions include voltage, current and resistance; in addition, there are extra functions that may also appeal to electrical and electronic engineers.
Page 5
Meter description 6000 counts LCD display. Push buttons for features Selection switch Input terminal for all other functions (Red) Input terminal for A current selection (Red) COM (Black) common or ground reference input terminal for all functions. Features...
Page 6
5. According to measured value the reading will be in Ω, kΩ or MΩ. Note: The AVO410 provides an open circuit voltage <-1.5 V to the circuit under test which will cause transistor junctions to conduct so it is advisable to disconnect the item to be tested from the circuit to obtain an accurate reading.
Page 7
4. For continuity connect the test probes to the cable or circuit to be tested. (Polarity is not important). 5. The AVO410 will emit a tone if continuity is below 500 Ω / .OL with no tone will indicate either open circuit or continuity above 500 Ω.
Page 8
5. Carefully apply the power 6. Read the measured on the display. 7. Remove supply before removing test leads and reconnecting circuit. FEATURE BUTTONS BACKLIGHT The AVO410 has a backlit display for all the different functions which has an auto off in 60 seconds.
Page 9
MIN MAX button once more will switch the instrument display to minimum reading. Pressing the HOLD button while in MIN MAX mode will stop the AVO410 up- dating the maximum and minimum displayed reading. Holding down the MIN MAX button for >1 sec. will switch the function off.
To clean the instrument, do not immerse in water, periodically wipe the case with a damp cloth and mild detergent. Dirt in the terminals may affect readings. Remove the battery if the AVO410 is not to be used for a long period of time. When the low battery symbol appears on the display, replace the battery.
ELECTRICAL SPECIFICATIONS Accuracy is ± (% reading + number of digits) at 23 ºC ±5 ºC, less than 80% R.H DC/AC volts Range DC accuracy AC accuracy 600.0 mV 50 Hz/60 Hz sine wave 6.000 only for 600.0 mV range, ±...
Page 12
Overload protection A input: 10 A (500 V) fast blow fuse µA input: 600 V rms AC conversion type: Conversion type and additional specification are the same as DC/AC voltage Resistance Range Accuracy Overload protection 600.0 Ω *2 6.000 KΩ ±...
Page 13
Frequency Range **Sensitivity Overload protection 6000 Hz 100 mV rms 60.00 KHz Frequency: 600.0 KHz 0.1% ±1 digit 6.000 MHz 250 mV rms 60.00 MHz 1 V rms Overload protection: 600 V rms * Less than 20 Hz, the sensitivity is 1.5 V rms ** Max.
Page 14
Note: Any unauthorised prior repair or adjustment will automatically invalidate the warranty. INSTRUMENT REPAIR AND SPARE PARTS For service requirements for Megger instruments contact: Megger Limited Megger Archcliffe Road Valley Forge Corporate Centre...
Page 15
Approved Repair Companies A number of independent instrument repair companies have been authorised for repair work on most Megger instruments, using genuine Megger spare parts. A list of approved companies is available from the UK address shown.
Page 16
NSW 2140 T: +61 (0)2 9397 5900 F: +61 (0)2 9397 5911 Megger products are distributed in 146 countries worldwide. The company reserves the right to change the specification or design without prior notice. Megger is a registered trademark Part No. AVO410_UG_V03 0313...
Need help?
Do you have a question about the AVO410 and is the answer not in the manual?
Questions and answers