AVAC9000CM[07]instructions
29/1/07
Installation
Exhaust Duct Set Assembly and Installation
Connect exhaust hose assembly to the back of the unit.
Extend hose to desired length and locate the exhaust
nozzle through the window for ventilation.
Insert both ends of the exhaust hose into the two
G
exhaust nozzle connectors by twisting anti-
clockwise until they stop.
Fix one of the connectors to the rear outlet of
G
the unit. This is achieved by sliding the nozzle
connector downwards over the exhaust outlet of
the unit ensuring that the lugs on the nozzle
connector are engaged with the grooves on the
connector of unit.
Fix the other exhaust nozzle connector to the
G
exhaust nozzle.
Extend the exhaust hose and close the window as
G
much as possible trapping the exhaust nozzle.
Semi-permanent Installation
If required, your appliance can also be installed
semi-permanently.
Drill a 125mm hole in an outside wall* or through a
G
window pane.
The unit should not be within 300mm of any wall.
G
Fit the flange accessory fixture provided in the hole.
G
Fit the exhaust hose in the housing at the back of the appliance.
G
Insert the other end of the exhaust hose to the flange previously fit on
G
the wall as shown in Fig.3.
When the hose is not in use, place the cap for connector to cover the
hole.
NOTE : When installing the air conditioner semi permanently, you should
leave a door slightly open (as little as 1cm) to guarantee sufficient
ventilation.
* Installing through an outside wall: you are recommended to insulate the
section of wall using suitable insulation material.
14:37
Page 6
Exhaust nozzle
Exhaust
hose
Exhaust nozzle
connectors (2)
6

Troubleshooting

The following cases may not always be a malfunction, please check
it before asking for service.
Problem
Analysis
Does not operate
If the protector tripped or fuse is blown.
Please wait for 3 minutes and start again,
protector device may be preventing unit to work.
If the plug is not properly plugged.
Stop during operation
If the set temperature is close to room
temperature, you can adjust the temperature.
Air outlet or intake be blocked.
Take the obstacle away.
Operating but not
If the door or window opened.
cooling
If there is other heater appliance working,
like heater or lamp, etc.
The air filter is dirty, please clean it.
Set temperature is too high.
Air outlet be blocked by obstacle.
Does not operate and
Drain the water into a prepared container by
water full indicator is lit the drainage pipe on the rear panel of the
unit. If still doesn't work, please consult a
qualified technician.
Maintenance
Maintenance after using
If unit is quite dirty use a mild detergent and damp cloth.
1
If the appliance will not be used for a long time, be sure to pull out the rubber
drainplug to allow the water to drain.
2
Before storing away run the unit in fan mode only for few hours to dry any
moisture on the coils to prevent mould.
3
Clean the air filter and reinstall it.
4
Remove the air hoses and store; cover the wall vent with the supplied cap.
7