NewMar 12-1800IC Installation & Operation Manual page 20

Guided wave series inverter/chargers
Table of Contents

Advertisement

12 Volt Models
Switch
Position
A
B
C
D
24 Volt Model
Switch
Position
A
B
C
D
32 Volt Model
Switch
Position
A
B
C
D
Operating Temperature (all models): -22° C to +40° C (0° F to 104°F)
Mechanical Features (all models):
! Thermally controlled cooling fan
! GFCI protected duplex outlets
! Powder coated aluminum case with integral mounting flanges
! Conformal coated printed circuit boards
Protection Features (all models):
! Automatic low battery shutdown
! Output circuit breakers
! Auto high temperature shutdown/recovery
! Short circuit protection
! Overload protection
Compliance: UL 458 Listed
Options
! Remote control and indicator panel; provided with 25' of cable. Model: ICR-2
! Battery Integrator for charging multiple output banks*. Models: BI-100, BI-24-100
*Not available for 32 volt systems; contact factory for alternate methods
! Digital DC Energy monitor for precise indication of battery volts, amps, amp-hours used
and remaining. Includes programmable high/low voltage remote alarms. Model: DCE
20
P.O. Box 1306
Newport Beach,
California 92663
Use For
Equalization CAUTION
Equalization CAUTION
Flooded/AGM Charging
Gel-Cell Charging
Use For
Equalization CAUTION
Equalization CAUTION
Flooded/AGM Charging
Gel-Cell Charging
Use For
Equalization CAUTION
Equalization CAUTION
Flooded/AGM Charging
Gel-Cell Charging
www.newmarpower.com
Output Voltage (VDC)
@ Charge
@ Float
15.2
13.2
14.6
13.2
14.2
13.2
13.8
13.2
Output Voltage (VDC)
@ Charge
@ Float
30.4
26.4
29.2
26.4
28.4
26.4
27.6
26.4
Output Voltage (VDC)
@ Charge
@ Float
40.7
35.2
39.2
35.2
37.9
35.2
36.8
35.2
E-Mail: sales@newmarpower.com
Phone: 714-751-0488
Fax: 714-957-1621

Hide quick links: