K) Remote Panel (Optional) - NewMar 12-1800IC Installation & Operation Manual

Guided wave series inverter/chargers
Table of Contents

Advertisement

CAUTION: Do not connect any other source of AC power directly to the output of the inverter.
This will result in damage not covered under the warranty.
30 amps is the maximum AC current output of the entire inverter including AC hard-wire
output and both outlets (and also the current supplied to the battery charger if the AC
source is external). The inverter's internal wiring is over-current protected by a resettable 30
amp "Output" breaker located beside the "Branch" output breaker on the front panel.
IMPORTANT INSTALLATION NOTE: Per ABYC Section A-25 a label must be installed at the
main electrical panel to warn anyone who may work on that panel that an inverter has been
installed. This is because it might be falsely assumed that after the AC main has been shut
off the panel is no longer "hot", when in fact it may still be operating, due to the automatic
functioning of the inverter. A set of AC distribution panel warning labels has been provided
in the installation kit. Choose the preferred black or white background label and affix it in a
clearly visible location at the panel.
CAUTION: The AC outlets and AC hard-wire outputs on the inverter remain "live" when
derived from an external source, even when the inverter is shut off.

K) Remote Panel (Optional)

Remote monitoring of inverter/charger functions, as well as inverter output activation/shut-
off, may be obtained using model ICR-2 Remote Panel, available from NEWMAR. The panel
duplicates all of the LED status indicators (discussed in sections IV and V following) which
are on the front panel and incorporates a secondary on-off switch for the inverter.
FIGURE 4: Remote Panel Installation
PANEL DIMENSIONS: 4 1/2" HIGH x 4 1/2" WIDE
PANEL REAR CUT-OUT AREA
(for bulkhead mount): 2 7/8" HIGH x 3 3/4" WIDE
REMOVE FACTORY INSTALLED
"DUMMY" PLUG AND INSERT
REMOTE PANEL IN-LINE PLU
P.O. Box 1306
Newport Beach,
California 92663
+
-
G
www.newmarpower.com
MOUNT PANEL IN DOUBLE-GANG
DUPLEX OUTLET BOX OR USE
FOUR PROVIDED SCREWS FOR
BULKHEAD MOUNT
25' CABLE SUPPLIED
WITH REMOTE PANEL
E-Mail: sales@newmarpower.com
11
Phone: 714-751-0488
Fax: 714-957-1621