Restore Factory Defaults - Spectracom 8183A NETCLOCK Instruction Manual

Netclock/gtp gps master clock
Table of Contents

Advertisement

4.5

RESTORE FACTORY DEFAULTS

The DEF command returns all selectable parameters to the factory default settings.
The clock must be placed in Test Mode to execute the DEF command. The factory
default settings are listed below:
FRONT PANEL FORMAT= 24 HOUR
TIME DIFF= +00:00 DST= 0
IRIG FORMAT= FAA
TIME DIFF= +00:00 DST= 0
SERIAL PORT 1
BAUD RATE= 9600 FORMAT #= 00 REQUEST CHAR= T
TIME DIFF= +00:00 DST= 0
SERIAL PORT 2
BAUD RATE= 9600 FORMAT #= 00 REQUEST CHAR= T
TIME DIFF= +00:00 DST= 0
REMOTE PORT 1
BAUD RATE= 9600 FORMAT #= 00
TIME DIFF= +00:00 DST= 0
LOCK TIME OUT= 00:15:00
SYNC TIME OUT= 02:00:00
To restore the clock to factory default settings enter the following:
Type:
Sample response:
Type:
Response:
NetClock/GTP Instruction Manual
TM ON <ent>
TIME= 15:31:57
DATE= 2001-04-18 STATUS CHANGE
ACTIVE ALARMS: MAJOR AND MINOR
IN TEST MODE
DEF <ent>
ALL PARAMETERS SET TO FACTORY DEFAULTS