Exacq Vision User Manual page 53

Network video recorder
Hide thumbs Also See for Vision:
Table of Contents

Advertisement

The following Event Types are available:
NOTE: Input Trigger is the only Event Type available on exacqVision Start systems.
Event Type
Video Motion
Video Loss
Input Trigger
Serial Port
Serial Profile
Health
IP Camera Connection
Soft Trigger
Time Trigger
Analytics
Source Group
The Event Source list varies depending on the Event Type selected:
Event Type Selected
Video Motion
Video Loss
Input Trigger
Serial Port
Serial Profile
Health
IP Camera Connection
Soft Trigger
Time Trigger
Analytics
Source Group
Description
Camera detects motion.
Analog video signal is disconnected.
Discrete input on hybrid server or IP camera with alarm input is activated.
Key word entered on Serial Profile page is detected on a pre-selected port.
Key word is detected on any Serial Port with that profile.
Detected problem involving the health of the exacqVision server hardware.
Network can't connect to the IP Camera.
Signal sent from the client to the server.
Time of day or day of week reached.
Video analytics event detected.
Multiple event types for advanced event linking.
Event Source
Any of the cameras connected to the exacqVision server.
Any analog camera connected to the exacqVision server.
Any input trigger on the back of the server or IP camera connected to the
server. The system defaults to a device and input number, but these can be
customized on the Trigger Input page. See the "Trigger Inputs" section of this
manual for details.
Any of the serial ports configured on the server. See the "Serial Ports" section
of this manual for details.
Any of the serial profiles you have configured. You can select all key words
associated with a serial profile by selecting the profile name, or you can select
an individual key word configured in the profile.
Includes failures or temperature problems on a device; problems with storage
configuration; subscription expiration; video throttling alarms; alarms related
to parameters monitored on the Hardware Monitoring tab on the System
page; failed connection to shared network drive for archiving.
Any of the IP cameras connected to the exacqVision server.
Select New to create a new soft trigger with a default name. Double-click to
name it, or click Delete to remove it. You can also select any of the pre-
configured soft triggers that are listed.
Select New to open a window. Name the time trigger, select a start and end
time, and select the days of the week when the selected action should occur.
(For example, you could perform an Auto Export at 2:00 every morning.)
A list of video analytics events (configured through the provider's interface).
Select New to open a window. You can then select any combination of event
types and event sources and determine whether any or all of them must
occur to trigger the selected action.
www.exacq.com
+1.317.845.5710
+5255.56080817
+44.1438.310163
53
USA (Corporate Headquarters)
Mexico
Europe/Middle East/Asia

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Exacq Vision

This manual is also suitable for:

Exacqvision

Table of Contents