Potterton Combi 80 Installation & Service Instructions Manual page 8

Table of Contents

Advertisement

Installation Requirements - Page 8
135° Off-set kits are available for both concentric and
twin tube.
A Pitched Roof Flashing kit and Flat Roof Flashing kit
are available for use with the vertical flue systems.
If a horizontal flue is sited less than 2 metres above a
balcony, above ground, or above a flat roof to which
people have access, a suitable terminal guard must be
fitted. This serves two purposes, to protect the terminal
against damage or interference and to protect passers-
by.
Note: Where a flue terminal is installed less than 1
metre from a plastic, or painted gutter, or 500 mm from
painted eaves, an aluminium shield 1 metre long, should
be fitted to the underside of the gutter or painted
surface. A suitable wall plate should be fitted to the
painted wall surface of a mobile home.
IMPORTANT: It is absolutely ESSENTIAL, to ensure
that products of combustion discharging from the
terminal cannot re-enter the building, or any other
adjacent building, through ventilators, windows, doors,
natural air infiltration, or forced ventilation/air
conditioning. If products of combustion are found to be
re-entering any building, the appliance MUST be turned
OFF IMMEDIATELY.
POSITION
A
DIRECTLY BELOW AN OPENABLE
WINDOW, AIR VENT, OR ANY OTHER
VENTILATION OPENING
B
BELOW GUTTER, DRAIN/SOIL PIPE
C
BELOW EAVES
D
BELOW A BALCONY/CARPORT ROOF
E
FROM VERTICAL DRAIN PIPES AND
SOIL PIPES
F
FROM INTERNAL OR EXTERNAL CORNERS
G
ABOVE ADJACENT GROUND OR BALCONY
LEVEL
H
FROM A SURFACE FACING THE TERMINAL
I
FACING TERMINALS
J
FROM OPENING (DOOR/WINDOW) IN
CARPORT INTO DWELLING
K
VERTICALLY FROM A TERMINAL ON THE
SAME WALL
L
HORIZONTALLY FROM A TERMINAL ON
THE SAME WALL
M
ADJACENT TO OPENING
N
ABOVE ROOF LEVEL (TO BASE OF TERMINAL)
P
FROM ADJACENT WALL TO FLUE
Q
FROM INTERNAL CORNER TO FLUE
R
BELOW EAVES OR BALCONY
S
FROM FACING TERMINAL
MIN. DISTANCE mm
300
75
200
200
75
25
300
600
1200
1200
1500
300
300
300
210
230
600
1200

Hide quick links: