Installation Requirements - Page 12
Inhibitors
When the heating system has been completed, it should
be cleaned thoroughly in accordance with BS 7593
(code of practice for Treatment of Water in Domestic Hot
Water Central Heating Systems) to prevent foreign
matter from entering the boiler.
Ideally, it should be flushed before the boiler is
connected, and again after the system has been heated
and is still warm. BetzDearborn Sentinel X300 or Fernox
Superfloc are our recommended cleansers for new
systems.
Where a boiler is being fitted as a replacement to an
existing system, it is best practice to clean the system
prior to fitting the new boiler. In this case BetzDearborn
Sentinel X400 or Fernox Superfloc should be used.
In order to minimise corrosion in the system, inhibit scale
formation and microbiological growth, we recommend
that an inhibitor is added to the system when it is refilled
following the final (hot) flushing. BetzDearborn Sentinel
X100 or Fernox MB-1 are suitable products.