12. INSTALLATION

WARNING!
Refer to the Safety chapters.
The built-in unit must meet the
stability requirements of DIN
68930.
The oven is designed to be connected
to 230 - 240V ~ (50Hz) electricity supply.
The oven has an easily accessible termi-
nal block which is marked as follows:
Connection via
Cooker Control
Circuit
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a mini-
mum gap of 3 mm between the switch
contacts and of a type suitable for the
required load in compliance with the
current regulations.
The switch must not break the yellow
and green earth cable at any point.
After installation and connecting,
the cable must be placed so that
it cannot at any point reach a
temperature of more than 50°C
above the ambient temperature.
Before the oven is connected,
check that the main fuse and the
domestic installation can support
the load; and that the power sup-
ply is properly earthed.
Min. size Cable/
flex
2,5 mm²
on the front frame of the appliance cavi-
ty.
.........................................
.........................................
.........................................
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to
the electrical supply must comply to the
specifications given below.
For UK use only
Cable/flex type
PVC / PVC twin
and earth
The manufacturer declines any respon-
sibility should these safety measures
not be carried out.
Fuse
min: 15 A
max: 20 A