4. H f
Adjustment
o
Purpose: To get correct horizontal frequency.
Symptom of Misadjustment: . If H f
correct, skew distortion will appear on the screen.
Test Point
Adj. Point
CHo / p button
R583
["H-ADJ"]
MODE
Tape
M. EQ.
Frequency
---
Counter
Note: R583 --- Main CBA
Use Service remote control unit.
1. Connect Frequency Counter to R583 and ground.
2. Set the unit to the VIDEO mode which is located
before CH2 and no input is necessary. Enter the
Service mode. (See Page 5-1)
3. Operate the unit for at least 20 minutes.
4. Press " 2 " button on the Service remote control
unit and select H-ADJ Mode. (By pressing " 2 " but-
ton the display will change from TV AGC to H-ADJ)
5. Press "CH o / p" button on the Service remote
control unit so that the display will change "0" ~ " 7 ".
At this moment, Choose display one of them from
"0" ~ " 7 " when the Frequency Counter shows
15.734 kHz±300Hz or closer.
6. Turn the power off and on again. (Main Power but-
ton on the TV unit.)

5. VCO Adjustment

Purpose: To operate VCO correctly.
Symptom of Misadjustment: VCO does not work
correctly and/or synchronization is faulty.
Test Point
Adj. Point
---
---
Tape
M. EQ.
---
---
Note: Use service remote control unit.
1. Disconnect the RF input and set the unit to Channel 4.
2. Enter the Service mode. (See Page 5-1)
3. Press " 3 " button on the Service remote control
unit. The Auto VCO adjustment is started.
4. If the display color is changed from red to green,
This adjustment is done.
5. Turn the Power off and on again. (Main power but-
ton on the TV unit.)
adjustment is in
0
Mode
Input
---
Spec.
15.734kHz±300Hz
Mode
Input
No
signal
Spec.
---
5-3
6-1. AGC Adjustment
Purpose: Set AGC (Auto Gain Control) Level.
Symptom of Misadjustment: AGC does not syn-
chronize correctly when RF input level is too weak and
picture distortion may occur if it is too strong.
Test Point
Adj. Point
CHo / p
TP301
buttons
Tape
M. EQ.
Pattern
---
Generator DC
Volt Meter
Notes: TP301 --- Main CBA
Use Service remote control unit.
1. Enter the Service mode. (See Page 5-1) Then
press number " 2 " button on the Service remote
control unit.
2. Receive the Color Bar signal for channel 4
(67.25MHz). (RF Input Level: 60dBµV)
3. Press "CH o / p" buttons so that the voltage of
TP301 becomes +2.7±0.1V DC.
4. Turn the Power off and on again. (Main power but-
ton on the TV unit.)
6-2. FM AGC Adjustment
1. Enter the Service mode. (See page 5-1.) Then
press number "2" button twice on the remote con-
trol unit.
2. Press CH.o / p buttons so that the FM AGC
(MAX) level is 127.
7. Black Level Adjustment
Purpose: Set Sub-bright Level
Symptom of Misadjustment: If Sub-brightness is
incorrect, Proper brightness can not be obtained by
adjusting the Brightness Control.
Note: TP300 (GND), D316 (Cathode) --- MAIN CBA
1. Enter the Service mode. (See page 5-1).
2. Press " MENU " button on the Service remote con-
trol unit and select " BRT " mode. (Display chang-
es " BRT ", " CNT ", " CLR " and " TNT " cyclically
when MENU button is pressed).
3. Press "CH o / p" buttons on the Service remote
control unit so that the value of " BRT " becomes
128.
4. Turn the power off and on again. (Main power but-
ton on the TV unit.)
Mode
Input
Color Bar
RF
67.25MHz
60dBµV
Spec.
+2.7±0.1VDC
L6310EA