Make Electrical Connection; Install Vent Covers - Whirlpool 30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNTCANOPY RANGE HOOD Installation Instructions Manual

30" and 36" (76.2 and 91.4 cm) wall-mount canopy range hood
Hide thumbs Also See for 30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNTCANOPY RANGE HOOD:
Table of Contents

Advertisement

Available languages

Available languages

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install a UL
listed or CSA approved ¹⁄₂" strain relief.
A. Knockout
B. Terminal box
C. Terminal box cover
4. Run home power supply cable through strain relief, into
terminal box.
A
C
D
E
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
A
B
C
B
F
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
5. Use UL listed wire connectors and connect black wires (C)
together.
6. Use UL listed wire connectors and connect white wires (E)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the "Assistance or Service"
section for information on ordering.
NOTE: Use only with range hood cord connection kits that have
been investigated and found acceptable for use with this model
range hood.

Install Vent Covers

When using both upper and lower vent covers, push lower cover
down onto hood and lift upper cover to ceiling and install with
2 - 4.2 x 8 mm screws.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
B
A
A. Bracket
B. 4.2 x 8 mm screws
C. Vent cover
C
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

30"36"

Table of Contents