Chapter 7: Device Management

Power Supply Setup

134
Trap Name
userSessionTimeout
vmImageConnected
vmImageDisconnected
The Dominion KX II provides dual power supplies, and can automatically
detect and provide notification regarding the status of these power
supplies. Use the Power Supply Setup page to specify whether you are
using one or both of the power supplies. Proper configuration ensures
that the Dominion KX II sends the appropriate notifications should a
power supply fail. For example, if power supply number one fails, the
power LED at the front of the unit will turn red.
To enable automatic detection for the power supplies in use:
1. Choose Device Settings > Power Supply Setup. The Power Supply
Setup page opens.
2. If you are plugging power input into power supply number one
(left-most power supply at the back of the unit), then select the
Powerln1 Auto Detect option.
3. If you are plugging power input into power supply number two
(right-most power supply at the back of the unit), then select the
Powerln2 Auto Detect option.
Description
A user with an active session has experienced a
session termination due to timeout.
User attempted to mount either a device or image
on the target using Virtual Media. For every attempt
on device/image mapping (mounting) this event is
generated.
User attempted to unmount a device or image on
the target using Virtual Media.