Page 1
HD IR Waterproof Fixed IP Camera (With Integrated Bracket) User’s Manual Version 3.2.3...
Page 2
Welcome Thank you for purchasing our IP camera! This user’s manual is designed to be a reference tool for your system. Please read the following safeguard and warnings carefully before you use this series product! Please keep this user’s manual well for future reference!
Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to your local electrical safety codes. The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited power source is rated 12V DC or 24V AC in the IEC60950-1. This series product can not support these two modes at the same time.
Page 4
Do not touch the CCD (CMOS) optic component. You can use the blower to clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is too much dust, please use the water to dilute the mild detergent first and then use it to clean the device.
1 General Introduction 1.1 Overview This series IP camera integrates the traditional camera and network video technology. It adopts audio and video data collection, transmission together. It can connect to the network directly without any auxiliary device. This series IPC uses standard H.264 video compression technology and G.711a audio compression technology, which maximally guarantee the audio and video quality.
The enclosure conforms to the IP 66 protection. Has the waterproof function. 1.3 Specifications 1.3.1 Performance Please refer to the following sheet for IPC performance specification. Model IPC- IPC- IPC-HFW3300C IPC-HFW3200C Parameter HFW3100C HFW3101C TI Davinci high performance DSP Main Processor...
Page 8
NTSC: NTSC: NTSC: NTSC: Main stream Main stream Main stream: Main stream: (3M@15fps ,10 (1080P@30fps, (1.3M@30fps, (1.3M@30fps, 80P@30fps, SXGA@30fps, 720P@30fps, 720P@30fps, SXGA@30fps, 1.3M@30fps, 704*480@30fp 704*480@30fp 1.3M@30fps, 720P@30fps, s) s) 720P@30fps, 704*480@30fps Extra stream Extra stream 704*480@30fps ), (704*480@30f (704*480@30 ), Extra stream ps,352*240@3 fps,352*240@3...
Support AC24V/DC12V power. (Can not support these two modes at the Power same time.) 8W MAX (10W MAX when ICR switch) Power Consumption Working -10℃~+60℃ Temperature Working 10%~90% Humidify φ104*306.7 Dimensions(mm) 1250g(Excluding box) Weight Bracket is included in the accessories bag. Installation 1.3.2 Factory Default Setup Please refer to the following sheet for factory default setup information.
Page 10
Default Setup Setup Item IPC- IPC- IPC- IPC- HFW3300C HFW3200C HFW3100C HFW3101C Watermark DigitalCCTV character Enable Enable Bit stream General type Encode H.264 mode PAL:CIF(352*288) Resolution NTSC:CIF(352*240) Frame Rate PAL:25 Stream (FPS) NTSC:30 Bit Rate Type Recommen 192-1024Kb/S ded Bit Bit Rate 1024 I Frame...
Page 11
Default Setup Setup Item IPC- IPC- IPC- IPC- HFW3300C HFW3200C HFW3100C HFW3101C IP Version IPV4 IP Address 192.168.1.108 Subnet 255.255.255.0 Mask Default 192.168.1.1 Gateway Preferred 8.8.8.8 Alternate 8.8.8.8 Enable ARP/Ping device Enable address service Connection TCP Port 37777 Connection UDP Port 37778 HTTP Port RTSP Port...
Page 13
Default Setup Setup Item IPC- IPC- IPC- IPC- HFW3300C HFW3200C HFW3100C HFW3101C Alarm Delay 10 seconds Send Email Disable Snapshot Disable Enable Disable Record Enable Channel Record 10 seconds Delay Video Masking Relay out Enable Record 10 seconds Delay Send Email Disable Snapshot Disable...
Page 14
Default Setup Setup Item IPC- IPC- IPC- IPC- HFW3300C HFW3200C HFW3100C HFW3101C Send email Disable Enable Disable Record Enable Record 10 seconds Delay Disconnectio Relay out Enable Relay 10 seconds Delay Enable Disable Record Enable Record 10 seconds IP Conflict Delay Relay out Enable...
Page 15
Default Setup Setup Item IPC- IPC- IPC- IPC- HFW3300C HFW3200C HFW3100C HFW3101C Disable DST Type Week Start Time 00:00:00 of the first Sunday of the month End Time 00:00:00 of the second Monday of the month Disable NTP Server clock.isc.org Port Update 10 minutes...
2 Structure 2.1 Multiple-function Combination Cable You can refer to the following figure for multiple-function combination cable information. See Figure Figure 2-1 Please refer to the following sheet for detailed information. Port Name Function Connection Note Video output Output analog video signal. It can connect to the VIDEO OUT port TV monitor to view the video.
Port Name Name Note ALARM_COM Alarm output public port. Alarm output port. It is to output the alarm signal to the alarm device. ALARM_NO NO: normal open alarm output port. It works with the ALARM_COM port. I/O Port Alarm input port 1. It is to receive the on-off signal ALARM_IN1 from the external alarm source.
2.3 Bidirectional talk 2.3.1 Device-end to PC-end Device Connection Please connect the speaker or the MIC to the audio input port of the device. Then connect the earphone to the audio output port of the PC. Login the Web and then click the Audio button to enable the bidirectional talk function. You can see the button becomes orange after you enabled the audio talk function.
Page 19
Figure 2-4 Please refer to the following figure for alarm input information. See Figure 2-5. Alarm input: When the input signal is idle or grounded, the device can collect the different statuses of the alarm input port. When the input signal is connected to the 5V or is idle, the device collects the logic “1”.
3 Device Installation Please follow the steps listed below to install the device. Please refer to Figure 3-1 for reference. Please draw the installation holes in the installation surface and then mark three expansion bolts holes in the surface. Insert three bolts in the hole and secure firmly. Please line up the installation holes of the bottom of the pendant mount bracket to the installation holes in the surface.
4 Quick Configuration Tool 4.1 Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. 4.2 Operation Double click the “ConfigTools.exe”icon, you can see an interface is shown as in Figure 4-1.
Page 22
Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure 4-3. Figure 4-3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set.
5 Web Operation This series IPC product support the Web access and management via PC. Web includes several modules: monitor channel preview, PTZ control, system configuration, alarm and etc. 5.1 Network Connection Please follow the steps listed below for network connection. Make sure the IPC has connected to the network properly.
Page 25
Figure 5-2 If it is your first time to login in, system pops up warning information to ask you whether install control webrec.cab or not after you logged in for one minute. Please click OK button, system can automatically install the control. When system is upgrading, it can overwrite the previous Web too. If you can’t download the ActiveX file, please check whether you have installed the plug-in to disable the control download.
Page 26
Figure 5-4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction.
6 FAQ I can not boot up Please click RESET button for at least five seconds to restore the device. factory default setup. card write Do not set the SD card as the storage media to storage the times schedule record file. It may damage the SD card duration. I can not use the When disk information is shown as hibernation or capacity is 0, please format it first (Via Web).
Appendix Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Name Cr VI PBDE Circuit Board ○ ○ ○ ○ ○ ○ Component Device Construction ○ ○ ○ ○ ○ ○ Material Wire and Cable ○ ○...
Need help?
Do you have a question about the IPC-HFW3300C and is the answer not in the manual?
Questions and answers