4.4 CAN Connector (X6, X8)
Two 9-pin D-Sub male connectors are used for the CAN interfaces CAN0 and CAN1. Both
CAN interfaces can be used simultaneously.
Pin Number
Pin Signal
1
2
CANL
3
4
5
6
7
CANH
8
9
Shield
© Fujitsu Semiconductor Europe GmbH
Change odd page title here
Chapter 4 Connectors
Figure 4-3: CAN Connector
Description
NC
Not used
LOW-level CAN voltage input/output
GND
Ground
NC
Not used
NC
Not used
NC
Not used
HIGH-level CAN voltage input/output
NC
Not used
NC
Not used
GND
Ground
Table 4-2: CAN Connector Signals
- 27 -
FMEMCU-UG-960031-13