Figure 2 Vibrator Mechanism - Asus P565 Troubleshooting Manual

Hide thumbs Also See for P565:
Table of Contents

Advertisement

2.3.2 Vibrator Test
If the vibrator is not functioning, please check if VIBRA_C0 voltage
is measured at 3V and also no defect is found on component R1516 or
D1501, then it is likely that U1505 is defective.
2.3.3 RTC Test
It is rare to observe this type of defect, but if it does occur, please
examine if X301 crystal is sending out 32.768KHz clock signal correctly.
If 32.768KHz crystal is running correctly, then it is likely that U301
(CPU)
2.3.4 Storage Test
It is also rare to observe this type of defect, but if it does occur, it is
likely that U601 is defective.
2.3.5 MicroSD Test
If the device is unable to read SD storage card, try to replace the
device with new a sub-board and perform the test again. If the defect is
still not solved, please follow the following debugging procedure:
A. Please verify if sub board(MicroSD board) and main board is
connected properly.
B. Please verify if CON1201 is defective.
C. Please verify if MMC_PWR_EN = 1.8V (On the sub board.) If not,

Figure 2 Vibrator mechanism

GTC ■ Service Manual
20

Advertisement

Table of Contents
loading

Table of Contents