Sharp FU-A80J Operation Manual
Sharp FU-A80J Operation Manual

Sharp FU-A80J Operation Manual

Air purifier

Advertisement

FU-A80J
Free standing type
Device.of.this.mark.is.a.trademark.of.Sharp.Corporation.
Plasmacluster.is.a.registered.trademark.or.a.trademark.
of.Sharp.Corporation.
AIR PURIFIER

OPERATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Sharp FU-A80J

  • Page 1: Operation Manual

    FU-A80J AIR PURIFIER OPERATION MANUAL Free standing type Device.of.this.mark.is.a.trademark.of.Sharp.Corporation. Plasmacluster.is.a.registered.trademark.or.a.trademark. of.Sharp.Corporation.
  • Page 2 Please read before operating your new Air Purifi er Some odour ingredients absorbed by the fi lters may become separated and may be discharged. through. the. air. outlet. and. result. in. additional. odour.. Depending. on. the. usage environment, especially when the product is used in a condition signifi cantly more.
  • Page 3: Table Of Contents

    SPECIFICATIONS E-3 ........*From the air that is drawn through the fil- ter.system. Room.size.:.62m Thank. you. for. purchasing. the. SHARP. Air. Purifier.. Please. read. this. manual. carefully.. Before. using. this. product,. be. sure. to. read. the.section:.“Important.Safety.Instructions.” After.reading.this.manual,.keep.it.in.a. convenient.location.for.future.reference.
  • Page 4: Important Safety Instructions

    • Do not use near flammable gases and material such as insecticides, fragrances, and lit cigarettes. •. Do.not.use.in.humid.place.such.as.bathrooms. • Contact the nearest Sharp Approved Service Centre for any problems, adjustments, or repairs. •. This. appliance. is. not. intended. for. use. by. persons. (including. children). with. reduced. physical,.
  • Page 5: Cautions Concerning Operation

    CAUTIONS CONCERNING OPERATION •. Do.not.block.any.opening. • Do not use the unit near or on hot objects, such as stoves or heaters or radiators. •. Do.not.use.the.unit.with.the.wrong.position.. • Always.hold.the.handle.on.both.sides.of.the.unit.when.moving.it. Holding.the.front.panel.when.carrying.may.cause.it.to.detach,.thus.dropping.the.unit.and.resulting. in bodily injury. • Do not use without filters inside the unit. •...
  • Page 6: Part Names

    PART NAMES ILLUSTRATIVE DIAGRAM Air Outlet Air Inlet Handle Main Unit HEPA Filter BACK Deodorizing Pre Filter Dust Sensor Date Label Power Cord Plug INCLUDED •.Operation.manual...
  • Page 7: Main Unit Display

    MAIN UNIT DISPLAY 11 12 15 16 17 QUICK CLEAN Button / Quick Clean Indicator Light (green) (Plasmacluster) ON / OFF Button / (Plasmacluster) ON / OFF Indicator Light (green) CLEAN SIGN The.color.changes.according.to.the.air.condition. Green..Yellow..Red Clean.......Very.Impure (Plasmacluster) Sign (blue) FAN SPEED Indicator Light (green) FAN SPEED Button POWER Button...
  • Page 8: Filter Installation

    FILTER INSTALLATION Unplug the electrical cord before performing any maintenance. To maintain the quality of the fi lters, they are installed in the main unit and packed in plas- tic bags. Be sure to remove the fi lters from the plastic bags before using the unit. Remove the front Panel.
  • Page 9: Operation

    OPERATION Press to start / stop. CLEAN SIGN Unless.the.power.cord.has.been.unplugged,. The.Dust.Sensor.automatically.moni- the. operation. starts. in. the. previous. mode. it. tors dust pollution level and adjusts was.operated.in. fan.speed.accordingly. Press to select fan speed. FP-A80U Green Yellow Clean Very.Impure AUTO mode *The air purifi er operates the airfl ow speed automatically.according.to.the.interior.
  • Page 10: Maintenance

    MAINTENANCE Care Cycle : Whenever.dust.accumulates.on.the.unit.or.every..month. CLEANING THE FILTERS CLEANING THE UNIT Turn off the unit, and unplug the Wipe with a dry, soft cloth. power cord. For.stubborn.stains.or.dirt,.use.a.soft.cloth. dampened.with.warm.water. Remove the Front Panel. Do not use volatile fluids and detergents. (Refer.to.E-6) Benzine,.paint.thinner,.polishing.powder,.
  • Page 11: Filter Replacement Guidelines

    FILTER REPLACEMENT GUIDELINES Filter life varies depending on the room environment, usage, and location of the unit. If dust or odour persists, replace the filter. (Refer to “Please read before operating your new Air Purifier”) Replacement timing •HEPA filter About 2 years after opening •Deodorizing Pre filter About 2 years after opening HEPA filter...
  • Page 12: Troubleshooting

    TROUBLESHOOTING Before.calling.for.service,.please.review.the.Troubleshooting.chart.below,.since.the. problem.may.not.be.a.unit.malfunction.. PROBLEM SOLUTION (not a malfunction) The unit leaves smoke and • Clean or replace the filters as needed. (Refer to E-9) • Is the unit installed in a location that is difficult for the odours in the air. sensor.to.detect.cigarette.smoke? •.Are.the.dust.sensor.openings.blocked.or.clogged? ..(In.this.case,.clean.the.openings.).(Refer.to.E-8)
  • Page 13: For Customer Assistance

    Sharp. Please retain your sales documentation, as this should be produced to validate a warranty claim.
  • Page 14 VISIT OUR WEBSITE AT www.sharp.net.au OR CALL SHARP CUSTOMER CARE 1300 135 022 (LOCAL CALL COSTS APPLY WITHIN AUSTRALIA) SHARP CORPORATION OF AUSTRALIA PTY LTD FOR LOCATION ENQUIRIES WITHIN NEW ZEALAND REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.nz...
  • Page 15: Specifications

    SPECIFICATIONS Model FU-A80J Power.supply 230-240V..50.Hz Fan. Fan Speed Adjustment Speed. Rated.Power.(W) Operation Fan.Speed.(m /hour) Noise.Level.(dBA) Recommended.Room.Size Sensor Dust Filter.type HEPA filter / Deodorizing Pre filter Cord.Length. 2.0m Dimensions. 402mm.(W).×.245mm.(D).×.620mm.(H) Weight 8.0.kg *.Size.of.a.room.which.is.appropriate.for.operating.the.unit.at.maximum.fan.speed. Standby Power In. order. to. operate. the. electrical. circuits. while. the. power. plug. is. inserted. in. the. wall. outlet,. this.
  • Page 16 SHARP CORPORATION OF AUSTRALIA PTY.LTD. A. B. N. 40 003 039 405 .HUNTINGWOOD.DRIVE,.HUNTINGWOOD,.N.S.W..248 P.O.BOX.6827,.BLACKTOWN..N.S.W..248 SHARP CORPORATION OF NEW ZEALAND LIMITED 59.HUGO.JOHNSTON.DRIVE.PENROSE,.AUCKLAND Printed.in.Thailand TINS-A499KKRZ..J-. ..TH.....

Table of Contents