1) Table for camera ID(Detail B : Address switch)
Camera ID
SW 1
SW
2
SW
3
SW
4
SW
5
SW
6
SW
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
OFF
10
OFF
ON
OFF
ON
OFF
OFF
OFF
11
ON
ON
OFF
ON
OFF
OFF
OFF
12
OFF
OFF
ON
ON
OFF
OFF
OFF
13
ON
OFF
ON
ON
OFF
OFF
OFF
14
OFF
ON
ON
ON
OFF
OFF
OFF
15
ON
ON
ON
ON
OFF
OFF
OFF
255(Abbreviation)
2) Protocol and Baud rate setting(Detail C : Setup switch)
Protocol
Baud rate
Setup switch
SW 1
SW 2
SW 3
SW 4
OFF
OFF
2400bps
4800bps
O
N
O
Baud rate
9600bps
OFF
O
ON
NONE
ON
Pelco D Protocol
OFF
OFF
O
N
O
FF
SK-P
Protocol
Protocol
OFF
N
(AUTO)
O
ON
ON
NONE
※After setting above combination, turn off and on.
<Caution> 1. Please make sure the ID and protocol, it may not work in accordance
with environment of setting.
2. Factory default is PELCO - D 2400bps.
5
◐ PRODUCT OUTLINE & FEATURES
1. Product outline
This surveillance camera, as outdoor Pan/Tilt/Zoom dome, can be
controlled by using controller, SK-AR11/R1, SK-AR12, and SK-AR13
and DVRs with functions of 12Ⅹ optical zoom.
2. Features
1) Modern & contemporary design.
2) Fast spin ning speed from up to
3) 128 p resets. D well t ime i n each po sition can be s elected.
4) Rem ote c ontrol ava ilable via RS-485
5) Com patible wi th va rious DVR 's. (PELCO -D)
6) Built in th erma l sen sor a nd co oling fan
7) Impact-re sistant material. (Al umin um & Poly carb onat e)
8) Vandal proof and Weath er proof (I P66)
9) Up to 12Ⅹ opti cal z oom
◐ WARNING & CAUTION
1. Please study the instruction manual before your applications and keep it
for your future reference.
2. Do not install the camera on a unstable surface. It will cause falling or
other hazards.
3. Do not use improper power, it could cause fire or electric shock.
4. Do not disassemble or remodel the camera, it could cause fire, electric
shock or other hazards.
5. This product should be installed by expert installer.
6. Do not install the product at the position exposed to the direct sun light.
7. Do not install the product where lighting is unstable.
8. Do not drop, hit strongly nor vibrate the product.
9. Unplug it when any inflammable or conductive material goes into the
product.
10. This product is produced only for the power 12V DC 1.5A.
2
3. Cable connections
7
SW
8
OFF
1
12V DC
12V DC, 1.5A input
OFF
2
GND
OFF
3
VIDEO
Connected to monitor
OFF
4
GND
OFF
5
RS-485A
Connected to controller or DVR
OFF
6
RS-485B
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Detail "D"
Connect the camera using the supplied terminal block
1) Connect the control unit via a twisted, 2-conductor line(maximum
length 1200m) to the pin array 5(RS485A) and 6(RS485B).
FF
Connect all cameras in parallel to this 2-conductor control line.
2) Feed the video signal at contact 3 via a shielded cable to the video
N
input of the following unit(e.g. Monitor, camera switcher, video splitter).
Connect the shield to contact 4. With a cable length of more than
300m a video amplifier should be inserted between the camera and
the cable to compensate for the line-level loss.
3) For power supply, connect a regulated 12V DC power supply unit
with a permanent rating of 1.5A or greater to contact 1(12V DC) and
the contact 2(ground).
<Caution>
Keep the pin array in mind.
And be sure to connect power only after all the installation is complete.
[Warning]
In case wrong connected power cable, may result in an electric shock,
fire, and or other hazard.
6
◐ DIMENSION
Ø100
200
per second.
Ø150
◐ MOUNTING & INSTALLATION
First remove the white plastic shipping protection from the inside of the
case allowing the camera to move freely.
1. Termination switch
Used for RS-485 communication
ON
: Apply to terminal unit when communicating with PC or remote
control in 1:1 or in multi-communication.
(Apply when communication error occurs)
OFF
: Apply to all the cameras except terminal(final) unit in multi-
communication.
<Caution> If the termination switch is ON more than 2 units, a trouble on commu-
nication may happen.
"A"
4. Camera installation
1) When you install the camera, you should install it after determining its
forward direction.
2) Self Tapping screws are included, but if you want to install it on a
concrete ceiling, you should use proper hardware.
3) Securely attach the lower part of the base on the ceiling. When installing
outdoors attach the supplied rubber pad onto the lower part of the base
so that no water may penetrate the screw holes and the cable entry.
<Movable range>
"D"
<Caution> When you assemble the seal ring, pay attention to the leakage.
2. ID setup
- Use it when you use many cameras or if you want to use a special
- You can address up to 255 units.(Please refer to the table for camera
- Optional remote control(model SK-AR11/R1) can control up to 99
Ø129
Detail "A"
3
SK-V109
FRONT
CAMERA FRONT
DIRECTION
REAR
360° Endless
<Caution>
5. Install complete
After finishing installation, when the power turn on, the camera module
move to initial position.
<Caution>
7
camera ID.
ID setup)
cameras.
ADDRESS
PROTOCOL
ON
OFF
ON
OFF
Detail "B"
Detail "C"
ID setup
Protocol/Baud rate setup
4
<Ceiling installation(Side piping)>
SCREW 4X25
4EA
PT 1/2
CABLE PIPE
WASHER SCREW
CAMERA'S
M3X8 3EA
ORIENTATION
MARK
RING SEAL 3EA
CABLE
CONNECTION
TORX T10
SCREW M3X15 6EA
<Ceiling installation(
Ceiling piping
)>
SCREW 4X25
4EA
WASHER SCREW
CAMERA'S
M3X8 3EA
ORIENTATION
MARK
RING SEAL 3EA
※The cabel must be pass
TORX T10
through a clamp then wrap
a cable half round a base
SCREW M3X15 6EA
when you are assembling.
Check out the angle of view before installation.
Please do not connect the power during installation.
8

Advertisement

loading

Summary of Contents for Huviron SK-V109

  • Page 1 - You can address up to 255 units.(Please refer to the table for camera controlled by using controller, SK-AR11/R1, SK-AR12, and SK-AR13 ID setup) and DVRs with functions of 12Ⅹ optical zoom. SK-V109/Z946 - Optional remote control(model SK-AR11/R1) can control up to 99 MANUAL cameras.
  • Page 2 ◐ OSD Menu configuration ◐ Specification OSD M ENU Model Number SK-V109 Z946 Motion Detection ON/OFF(8 areas) Set up Ca mera/ Pan, Tilt/ DisplayCamera: Set the general SSNR Low,Middle,High,Off camera menu except Sequence/Random Scan. Dig ital zoom Save the setting of location of Zoom/ Focus/ Camera setting.

This manual is also suitable for:

Sk-z946