Defrost
count start
ON
Power button
OFF
ON
Mode indicator
Dehumidification
OFF
mode
ON
Compressor
OFF
ON
Fan
OFF
ON
Solenoid valve
OFF
ON
Float switch
OFF
ON
Tank full indicator
OFF
Humidity
75%
12°C
Tube temperature
0°C
ON
High humidity warning
OFF
ON
Lights when room temperature is below 14˚C
Low temp indicator
OFF
ON
Swing
OFF
OFF
Louvre
ON
Swing
ON
OFF
ON
Louvre indicator
OFF
ON
Buzzer
OFF
ON
Drying inside
OFF
Defrosting / Tank full detection / High humidity warning
Defrosting
Defrosting
stop
start
40 min elapsed
Low priority
buzzer
Swing louvre
Tank full
Tank empty
detected
button
detected
3 sec
standby
Lights when room temperature is below 14˚C
Swing mode changes
Swing mode indicator changes
Power
Humidity
Humidity
OFF
increase
decrease
Flashes
Close
Close