Mitsubishi Electric MSZ-A09RV-E1 Service Manual page 11

Split-type, heat pump air conditioners, wireless type models
Table of Contents

Advertisement

MUZ-A09RV-
MUZ-A12RV-
E1
OUTDOOR UNIT
NOISE FILTER P.C BOARD
LD-E
GRN
TB1
12V
3
RED
220-240V ~
WHT
2
BLU
N
FROM INDOOR UNIT
CONNECTING
SYMBOL
NAME
CT61
CURRENT TRANSFORMER
C61,C62
SMOOTHING CAPACITOR
C65
OUTDOOR FAN CAPACITOR
DSA61
SURGE ABSORBER
F801
FUSE (2A)
F901
FUSE (2A)
IC950
DC/DC CONVERTER
IPM
INTELLIGENT POWER MODULE
LEV
EXPANSION VALVE COIL
L61
CMC COIL
NOTE:1. About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.
2.Use copper conductors only. (For field wiring)
3. Symbols below indicate.
/: Terminal block,
: Connector
MODELS WIRING DIAGRAM
E1
L63
TAB68
TAB69
LDNF2
LDNF1
BLU
WHT
RELAY
P.C
CN912
BOARD
L61
X61
X62
2
1
1
2
3
4
5
21S4
5
MF61
BLU
GRN/YLW
SYMBOL
L63
COIL
L64
REACTOR
MC
COMPRESSOR
MF61
OUTDOOR FAN MOTOR (INNER FUSE)
NR61
VARISTOR
PFC
POWER FACTOR CONTROL MODULE
RT61
DISCHARGE TEMPERATURE THERMISTOR
RT62
DEFROST THERMISTOR
RT64
FIN TEMPERATURE THERMISTOR
R61,62
CURRENT-DETECTING RESISTOR
LD62
PFC
WHT
LD61
BLU
R61
4
R62
4
+
C61
3
3
2
2
+
C62
1
1
IC950
F801
TRANS
R64
6
ELECTRONIC
CONTROL
P.C BOARD
6
5
CN601
4
1
2 3
3
2
1
NAME
11
6
LEV
~
-
TAB75
+
GRY
~
TB2
TAB76
BLK
LD65
U
P
LD66
V
N
LD67
RED
W
IPM
1
RT64
2
RT61
RT62
V
MC
SYMBOL
NAME
R64
CURRENT-DETECTING RESISTOR
R65
CURRENT-LIMITING RESISTOR
SSR61
SOLID STATE RELAY
TB1, TB2
TERMINAL BLOCK
X61, X62
RELAY
X64
RELAY
REVERSING VALVE COIL
21S4
(COOLING TURN ON)
GRY
L64
1
2
BLK
BLK
WHT
3
2
1
W
U

Hide quick links: