JVC AV-36F802/Y Service Manual page 257

Table of Contents

Advertisement

ADJUSTMENT OF CHROMA
Measuring
Item
instrument
SUB COLOR
Signal
adjustment
generator
Oscilloscope
Remote
control unit
Y
G
Cy
W
SUB TINT
Signal
adjustment
generator
Oscilloscope
Remote
control unit
Y
G
Cy
W
Test point
Adjustment part
TP-B
No.3 COLOR
TP-E1 (
)
[CRT SOCKET
PWB]
R
(A)
(–)
0V
(+)
B
Mg
TP-B
No.4 TINT
TP-E1 (
)
[CRT SOCKET
PWB]
R
(–)
0V
(+)
Mg
B
(B)
No. 51907B
Description
Notes:
• Proceed to the following this adjustment after having completed the
adjustment of CONTRAST.
• Set VIDEO STATUS to "STANDARD".
[ Method of adjustment without measuring instrument ]
1. Receive a broadcast.
2. Select the No.3 COLOR of the PICTURE MODE.
3. Set the initial setting value of the No.3 COLOR with the LEFT/RIGHT
key of the remote control unit.
4. If the color is not the best with the Initial setting value, make fine
adjustment of the No.3 COLOR until you get the optimum color.
Notes:
• Proceed to the following this adjustment after having completed the
adjustment of CONTRAST.
• Set VIDEO STATUS to "STANDARD".
[ Method of adjustment using measuring instrument ]
1. Input the full field color bar signal (75% white).
2. Select the No.3 COLOR of the PICTURE MODE.
3. Set the initial setting value of the No.3. COLOR with the LEFT/RIGHT
key of the remote control unit.
4. Connect the oscilloscope between TP-B and TP-E1.
5. Adjust COLOR and bring the value of (A) in the illustration to the
voltage +26V (V
).
W–B
Notes:
• Proceed to the following this adjustment after having completed the
adjustment of CONTRAST.
• Set VIDEO STATUS to "STANDARD".
[ Method of adjustment without measuring instrument ]
1. Receive a broadcast.
2. Select the No.4 TINT of the PICTURE MODE.
3. Set the initial setting value of the No.4 TINT with the LEFT/RIGHT
key of the remote control unit.
4. If the tint is not the best with the initial setting value, make fine ad-
justment of the No.4 TINT until you get the optimum tint.
Notes:
• Proceed to the following this adjustment after having completed the
adjustment of CONTRAST.
• Set VIDEO STATUS to "STANDARD".
[ Method of adjustment using measuring instrument ]
1. Input the full field color bar signal (75% white).
2. Select the No.4 TINT of the PICTURE MODE.
3. Set the initial setting value of the No.4 TINT with the LEFT/RIGHT
key to the remote control unit.
4. Connect the oscilloscope between TP-B and TP-E1.
5. Adjust TINT and bring the value of (B) in the illustration to the
voltvoltage +14V (V
).