Ambient Sensor Error
Is it displayed under picture?
Yes
Is the connection loose?
(CON6)
No
Power Off
Tip : To protection of MICOM)
Reconnect
Yes
34
Disconnect CON6 and
measure the value. Is
resistance value between
pins 7 & 8of CON6 as
below? (WH to WH)
Pin8 Pin7
Test Point
Result
6 ~ 400 ㏀
Pin3 to Pin 4
Yes
Reconnect CON6 and Power
ON
If the same situation appears,
Replace the main PCB.
Otherwise, explain to the
customer!
Replace
No
R-sensor