Finishing; Non-Combustible Materials; Combustible Materials; Hearth Extension - Heat & Glo RH-36 Series Owner's Manual

Wood burning fireplace installation and operation
Hide thumbs Also See for RH-36 Series:
Table of Contents

Advertisement

11

Finishing

A. Non-Combustible Materials
Materials which will not ignite and burn, composed of
any combination of the following:
-
Steel
- Iron
-
Brick
- Tile
-
Concrete
- Slate
-
Glass
- Plasters
Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace at 750° C
B. Combustible Materials
Materials made of or surfaced with any of the following
materials:
-
Wood
- Compressed paper
-
Plant fibers
- Plastic
Any material that can ignite and burn; flame proofed or
not, plastered or un-plastered
Table 11.1
R = 1/k x inches of thickness
Table 11.2
Hearth Extension Insulation Alternatives-Total minimum R Value must equal 1.03
Material
Hearth & Home HX3, HX4 (Micore 300™)
USG Micore 160™
USG Durock™ Cement Board
Cement Mortor
Common Brick
Ceramic Tile
Armstrong™ Privacy Guard Plus
Marble
38
k per inch
thick
0.49
0.39
1.92
5.0
5.0
12.50
0.46
14.3-20.0
Heat & Glo • RH-36/RH-42 • 4044-153 • Rev AC • 1/11
C. Hearth Extension
WARNING! Risk of fire! High temperatures, sparks,
embers or other burning material falling from the fireplace
may ignite flooring or concealed combustible surfaces.
Protective metal hearth strips MUST be installed.
Hearth extensions MUST be installed exactly as
specified.
You MUST use a hearth extension with this fireplace.
Refer to Figure 11.1 for minimum dimensions.
This fireplace has been tested and approved for use with
a hearth extension insulated to a minimum R value of
1.03.
The hearth extension material MUST be covered with
tile, stone or other non-combustible material.
Manufactured hearth materials will usually have a
published R value (resistance to heat) or k value
(conductivity of heat). Refer to the formula in Table 11.1
to convert a k value to an R value,
Refer to Table 11.2 for hearth extension insulation
alternatives.
Minimum
r per inch
thickness
thick
required
2.06
1/2 in.
2.54
1/2 in.
0.52
2 in.
0.20
5-1/8 in.
0.20
5-1/8 in.
0.08
12-1/4 in.
2.18
1/2 in.
0.07-0.05
14-5/8 in. - 20-3/8 in.