Vertical Sidewall Installation - Vermont Castings RFSDV22 Homeowner's Installation And Operating Manual

Freestanding direct vent fireplaces
Table of Contents

Advertisement

Vertical Sidewall Installation

Step 1
Locate the vent opening on the wall. It may be neces-
sary to first position the fireplace and measure to
obtain hole location. Depending on whether the wall is
combustible or noncombustible, cut opening to correct
size. (Fig. 14) For combustible walls, first frame in
opening.
Combustible Walls: Cut a 9³⁄₈" x 9³⁄₈" (240mm x
240mm) hole through the exterior wall and frame as
shown. (Fig. 14)
Noncombustible Walls: Hole opening must be 7¹⁄₂"
(190mm) in diameter.
Vent Opening for Combustible Wall
9³⁄₈"
(240mm)
9³⁄₈"
(240mm)
Fireplace Hearth
Vent Opening for Noncombustible Wall
7¹⁄₂'
(190mm)
Fig. 14 Locate vent opening on wall.
Step 2
Measure wall thickness and cut zero clearance sleeve
parts to proper length (MAXIMUM 12"). Assemble
sleeve and attach to firestop with #8 sheet metal
screws (supplied). Install firestop assembly. (Fig. 15)
Zero clearance sleeve is only required
for combustible walls.
Adjustable Zero
Clearance Sleeve
#8 Screws (2)
Adjustable Zero Clearance Sleeve
Fig. 15 Adjustable zero clearance sleeve.
10001028
RFSDV22/32/42 Freestanding Direct Vent Fireplace
Framing Detail
VO584-100
Max. Length
12" (294mm)
#8 Screws (2)
#8 Screws
(2)
Firestop
ZCS101
Step 3
Place fireplace into position. (Fig. 16) Measure the
vertical length (X) required form the base of the flue
collars to the center of the wall opening.
X
Fig. 16 Vertical length requirement.
Step 4
Apply a bead of silicone to the inner and outer flue
collars of the fireplace (Fig. 17) and using appropriate
length of pipe section(s), attach to fireplace with three
(3) screws. Follow with the installation of the inner and
outer elbow, again secure joints as described on Pages
8 and 9.
Bead of Sealant
Fig. 17 Apply a bead of silicone to the inner and outer flue
collars.
Step 5
Measure the horizontal length requirement including a
2" overlap, i.e. from the elbow to the outside wall face
plus 2" (or the distance required if installing a second
90° elbow). (Fig. 18)
FP1336
FP1337