Troubleshooting - Mitsubishi Electric Mr.Slim MS09NW Technical & Service Manual

Ductless split-type air conditioners wireless type
Hide thumbs Also See for Mr.Slim MS09NW:
Table of Contents

Advertisement

9

TROUBLESHOOTING

MUM30NN
9-1 Cautions on troubleshooting
9-1-1 Before troubleshooting, check the followings:
1) Check the power supply voltage.
2) Check the indoor/outdoor connecting wire for mis-wiring.
9-1-2 Take care the followings during servicing.
1) Before servicing the air conditioner, be sure to first turn off the remote controller to stop the main unit, and then after
confirming the horizontal vane is closed, disconnect the breaker.
2) When removing the P.C. board, hold the edge of the board with care NOT to apply stress on the components.
3) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.
9-2 Trouble criterion of main parts
Part name
Measure the resistance between the terminals with a tester.
(Coil wiring temperature-10¡C ~ 40¡C)
Compressor
Measure the resistance between the terminals with a tester.
(Coil wiring temperature-10¡C ~ 40¡C)
Outdoor fan
motor
WHT-BLK
BLK-YLW
YLW-BLU
BLU-RED
12
Check method and criterion
Normal(KH22WEV)
C-R
0.8~1.1'
C-S
4.8~5.2'
Normal(Upper)
60~75'
15~20'
12~16'
51~64'
Normal(RH167NAB)
2.1~2.7'
short-circuited
4.0~5.0'
Abnormal
Normal(Lower)
56~61'
Opened or
14~19'
short-circuited
12~16'
54~67'
Figure
Abnormal
Opened or
P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr.slim ms15nnMr.slim mum30nnMr.slim msm30nn

Table of Contents