Mitsubishi Electric PUZ-A18NHA4 Service Manual page 82

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for PUZ-A18NHA4:
Table of Contents

Advertisement

SW2 setting
LEV-A opening pulse on error occurring
0~480
ON
1
2 3 4 5 6
Indoor room temperature (TH1) on error
occurring
46~102
ON
1
2 3 4 5 6
Indoor pipe temperature / Liquid (TH2)
on error occurring
-38~190
ON
1
2 3 4 5 6
Indoor pipe temperature / Cond./ Eva.
(TH5) on error occurring
-38~190
ON
1
2 3 4 5 6
Outdoor pipe temperature / 2-phase
(TH6) on error occurring
-38~190
ON
1
2 3 4 5 6
Outdoor outside temperature (TH7) on
error occurring
-38~190
ON
1
2 3 4 5 6
Outdoor heatsink temperature (TH8) on
error occurring
-40~327
ON
1
2 3 4 5 6
Display detail
The black square (
Explanation for display
0~480
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
(Example) When 130 pulse;
0.5 secs.
46~102 (8~39°C)
-38~190 (-39~88°C)
(When the temperature is 0˚F or less, "–" and
temperature are displayed by turns.)
(Example) When –15˚F;
0.5 secs.
-38~190 (-39~88°C)
(When the temperature is 0˚F or less, "–" and
temperature are displayed by turns.)
(Example) When –15˚F;
0.5 secs.
-38~190 (-39~88°C)
(When the temperature is 0˚F or less, "–" and
temperature are displayed by turns.)
(Example) When –15˚F;
0.5 secs.
-38~190 (-39~88°C)
(When the temperature is 0˚F or less, "–" and
temperature are displayed by turns.)
(Example) When –15˚F;
0.5 secs.
-40~327 (-40~164°C)
(When the temperature is 0˚F or less, "–" and
temperature are displayed by turns.)
(When the temperature is 100˚F or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
82
) indicates a switch position.
0.5 secs. 2 secs.
1
30
0.5 secs. 2 secs.
15
0.5 secs. 2 secs.
15
0.5 secs. 2 secs.
15
0.5 secs. 2 secs.
15
Unit
Pulse
˚F
˚F
˚F
˚F
˚F
˚F